期刊文献+

刀锋伪影校正技术在精神疾病患者海马MRI检查中的应用 被引量:6

Imaging Hippocampus of Mental Patients with BLADE Technique
下载PDF
导出
摘要 为探讨磁共振刀锋伪影校正(BLADE)技术提升精神疾病患者海马磁共振图像质量的效果,本文分别使用结合了BLADE技术的BLADE T2WI TSE、BLADE T2WI FLAIR及传统T2WI TSE、T2WI FLAIR四种序列,对47例精神疾病患者和美国放射学院(ACR)标准模体在3.0 T磁共振成像(MRI)设备上分别进行常规海马斜冠状位扫描和ACR标准检测.患者的磁共振图像由2名放射科医师采用5分法对运动伪影、搏动伪影、颗粒度、海马磁共振图像质量进行评价,并应用Wilcoxon符号秩检验进行数据分析.模体图像通过识别图像的钻孔阵列和轮辐的数目,半定量评价各序列的高对比空间分辨力(HCSR)和低对比物体探测能力(LCD).结果表明相比传统序列,结合BLADE技术的序列能够明显改善海马磁共振图像的运动伪影、搏动伪影(p<0.001),提高图像质量(p<0.05);但在图像颗粒度方面,传统序列表现更优(p<0.001).ACR模体半定量分析显示,结合BLADE技术序列与传统序列相比,在LCD检测方面结果更优、在HCSR检测方面结果相同或略逊.本文推荐将BLADE技术应用于不合作的精神疾病患者海马的MRI检查. BLADE is the commercial name of a spin-echo imaging technique that uses periodically rotated overlapping parallel lines with enhanced reconstruction(PROPELLER)k-space trajectory.In this study,the efficiency of using BLADE to improve hippocampal imaging in mental patients was assessed.The hippocampi of 47 mental patients were imaged on a 3.0 T scanner along the oblique coronal orientation using the T2WI TSE and T2WI FLAIR sequences with or without the use of BLADE.The same four sequences were also used to scan a standard American College of Radiology(ACR)phantom according to the ACR standards.The hippocampal images were scored by two radiologists using a 5-point scale,in terms of motion artifact,pulsation artifact,perceptive coarseness and image quality.The outcomes were compared between the sequences by two-sample Wilcoxon tests.The images of the phantom were evaluated semi-quantitatively for high contrast spatial resolution(HCSR)and low contrast object detection detectability(LCD)by counting the number of hole arrays and spokes that could be detected.The results showed that,compared to the conventional sequences,the sequences combined with BLADE technique showed significantly reduced motion and pulsation artifacts(p<0.001),improved image quality(p<0.05),but increased the perceptive coarseness(p<0.001).In the phantom experiments,the use of BLADE greatly improved the LCD,but had little effects on the HCSR.Based on these results,the BLADE technique is recommended for hippocampal imaging in mental patients with low compliance with the guidance.
作者 邵丹丹 王雪雪 潘自来 陈克敏 张中帅 袁莉莉 许子悦 陈磊 王金红 SHAO Dan-dan;WANG Xue-xue;PAN Zi-lai;CHEN Ke-min;ZHANG Zhong-shuai;YUAN Li-li;XU Zi-yue;CHEN Lei;WANG Jin-hong(Department of Radiology,Ruijin Hospital North,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China;Department of Medical Imaging,Mental Health Center,Shanghai Jiao Tong University School of Medicine,Shanghai 200030,China;Siemens Healthcare,Shanghai 201318,China)
出处 《波谱学杂志》 CAS 北大核心 2019年第3期261-267,共7页 Chinese Journal of Magnetic Resonance
基金 上海市精神卫生中心特色学科建设资助项目(2017-TSXK-06)
关键词 刀锋伪影校正(BLADE) 磁共振图像 精神疾病 海马 BLADE magnetic resonance image mental disease hippocampus
  • 相关文献

参考文献2

二级参考文献33

  • 1俎栋林.磁共振成像学[M].北京:高等教育出版社,2004.101-103,241-243,271-274,507-529.
  • 2Forbes KP, Pipe JG., Karis JP, et al. Brain imaging in the unsedated pediatric patient:comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences[J]. AJNR, 2003,24:794-798.
  • 3Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging[J]. Magn Reson Med,1999,42:963-969.
  • 4Nishimura DG, Irarrazabal P, Meyer CH. A velocity k-space analysis of flow effects in echo-planar and spiral imaging[J]. Magn Reson Med, 1995,33:549-556.
  • 5Glover GH, Pauly JM. Projection reconstruction techniques for reduction of motion effects in MRI[J]. Magn Reson Med,1992,28:275-289.
  • 6Ahn CB, Kim HH, Cho ZH. High-speed spiral-scan echo planar NMR imaging[J].IEEE Trans Med Imaging,1986,5:2.
  • 7Meyer CH, Hu BS, Nishimura DG, et al. Fast spiral coronary artery imaging[J]. Magn Reson Med, 1992,28:202-213.
  • 8Ehman R, Felmlee J. Adaptive technique for high-definition MR imaging of moving structures[J].Radiology. 1989,173:255-263.
  • 9Ordidge RJ, Helpern JA, Qing ZX, et al.Correction of motional artifacts in diffusion-weighted MR images using navigator echoes[J]. Magn Reson Med,1994,12:455-460.
  • 10Sachs T, Meyer CH,Irarrazabal P, et al. The diminishing variance algorithm for real-time reduction of motion artifacts in MRI[J]. Magn Reson Med, 1995,34:412-422.

共引文献23

同被引文献39

引证文献6

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部