期刊文献+

考虑加工细节的局部无焊孔梁柱节点断裂性能

Fracture properties of local non-scallop beam-column joints considering processing details
下载PDF
导出
摘要 国内外对局部无焊孔的钢结构梁柱节点早有应用.梁柱连接部位,由于受到加工工艺影响容易产生人为缺陷.为了探索对局部无焊孔节点的断裂性能影响不大的允许缺陷,围绕无焊孔工法的加工细节提出存在些许缺陷的节点模型,通过焊接模拟和拟静力分析来比较含有不同加工细节的局部无焊孔节点的断裂性能.结果表明:简化衬板加工细节的节点断裂性能与标准工艺下的局部无焊孔节点断裂性能相当,因此钢衬板端部圆弧允许偏差存在;在凹坑处放置“楔块”的加工细节能有效地减小开裂指数,也便于实际操作.两种加工细节方案均具有应用价值. The steel beam-column joints with local non-scallop method have long been used both at home and abroad.Some artificial defects are easily caused in beam-column joints affected by processing technology.In order to explore the allowable defects which have little influence on the fracture properties of the local non-scallop joints,in this paper,the fracture properties of local non-scallop joints with different processing details are compared through the welding simulation and quasi-static analysis,and the joint models with some defects are proposed in consideration of the processing details of non-scallop method.The results show that the fracture properties of the joints with simplified processing details of backing plate is almost equivalent to that of the local non-scallop joints under the standard processing technology;therefore,a little deviation is allowed at the arc part of steel backing plate end.The processing details of placing“wedge”in the pit can effectively reduce the rupture index and be easy to operate in practice.Therefore,both projects of processing details have application value.
作者 王影 李军 胡蓉 丁洪斌 WANG Ying;LI Jun;HU Rong;DING Hong-bin(School of Civil Engineering,Qingdao University of Technology,Qingdao 266033,China;Qingjian Group Co.,Ltd.,Qingdao 266071,China)
出处 《青岛理工大学学报》 CAS 2019年第4期1-5,90,共6页 Journal of Qingdao University of Technology
基金 山东省住房和城乡建设厅研究开发项目(KY060)
关键词 断裂性能 焊接模拟 拟静力分析 加工细节 局部无焊孔梁柱节点 fracture property welding simulation quasi-static analysis processing detail local non-scallop beam-column joint
  • 相关文献

参考文献3

二级参考文献21

  • 1刘芸,王燕,王薇.焊接残余应力对加强型节点力学性能影响研究[J].建筑钢结构进展,2013,15(1):37-44. 被引量:6
  • 2Engelhardt M D, Sabol T A. Reinforcing of Steel Moment Connections with Cover Plates: Benefits and Limitations[J].Engineering Structures, 1998, 20(6) : 510 - 520.
  • 3Plumier A. New Idea for Safe Structures in Seismic Zones [C]//Proeeedings of the IABSE Symposium. Brussels: Uni- versity of Liege, 1990.
  • 4Engelhardt M D. Design of Reduced Beam Section Moment Conneetions[C]//Processing North American Steel Construc- tion Conference. Chicago: 1999.
  • 5中込忠男,矢部喜堂,坂本真一.梁スカラッフ.の有無がH形断面柱に溶接接合されるH形鋼梁端部のカ学的性状に及ぼす影響[J].日本建築学会構造系論文報告集,1992:51- 59.
  • 6田淵基嗣,金谷弘,回中丈之,等.角形鋼管柱?梁仕口溶接部における改良型スカラッフ.工法の提案[J].鋼構造年次論文報告集,1993,1:65 -72.
  • 7中込忠男,藤田哲也.魚型鋼管柱に通しダイアブラム形式で溶接接合される圧延H形鋼梁端部の力学的性状(梁スカラッフ.の有無および形状と目違いが破壊性状に及ぼす影響)[J].日本建築学会構造系論文報告集,1994:187 - 196困.
  • 8日本建第学会.建篥工事檩犟仕檬害lASS6铁骨工事[s].2007.
  • 9日本建篥学会.铁骨工事技衍指针·工埸制作编[S].2007.
  • 10Nakashima M. Classification of damage to steel buildings observed in the 1995 Hyogoken-Nanbu earthquake[J]. Engineering Structures, 1998,20(4-6) : 271-278.

共引文献5