期刊文献+

循环水泵断轴原因分析及改进措施 被引量:4

Cause Analysis on Fracture of Circulating Water Pump Shaft and the Improvement Measures
下载PDF
导出
摘要 U-GA-1001A循环水泵更换泵头后,泵轴发生断裂故障,通过对断轴的取样解剖、断口的宏观形貌分析、材料的化学成分分析、键槽材料金相检查发现:循环水泵轴的断裂是由于泵轴中心数据的变化导致的,也就是设备本身发生了位移所引起的。通过分析找到产生位移的原因,采取阻断泵偏移的路径、注意安装细节、掌握好各项数据等措施,检修至今设备运行稳定。 After the U-GA-1001A circulating water pump is re-applied,the pump shaft was fractured.Based on sampling and dissection of the fractured shaft,the macroscopic morphology analysis of the fracture surface,the chemical composition analysis of the material,and the metallographic examination of the keyway material,it is found that the fracture of circulating water pump shaft is caused by the change of the pump shaft center data,that is,the displacement of the equipment itself.The factors that cause the displacement are found through analysis,the path of the pump offset is blocked,the installation details are carefully observed,and the various data are mastered.Consequently,the equipment has been operated stably since the maintenance.
作者 徐卫斌 Xu Weibin(Olefins Division,SINOPEC Shanghai Petrochemical Co.,Ltd.,Shanghai 200540)
出处 《石油化工技术与经济》 2019年第4期48-52,共5页 Technology & Economics in Petrochemicals
关键词 循环水泵 轴断裂 原因分析 整改措施 circulating water pump shaft fracture cause analysis corrective measures
  • 相关文献

同被引文献21

引证文献4

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部