期刊文献+

CT系统高级扫描方式的图像质量测量方法 被引量:2

A measurement method for image qualities of advanced scanning techniques of CT systems
下载PDF
导出
摘要 目的:设计椭圆体模,对X射线计算机断层扫描(CT)系统中的高级扫描方式的图像质量进行评估。方法:制作兼容Catphan的椭圆体模,在3个不同品牌的CT扫描系统上使用自动曝光控制(AEC)、低剂量扫描和双能扫描3种高级扫描模式,对图像的CT值准确性和均匀性及层厚进行测量;在其中的两个支持双能的CT扫描系统上进行双能物质分解准确性的测量。结果:应用椭圆体模在各高级扫描模式下测量的图像质量无明显下降,能够满足国家的强制图像质量标准;两个CT扫描系统的双能扫描的物质分解准确度在±20%以内。结论:所设计的椭圆体模能够对CT系统的高级扫描条件下图像进行质量评估,并可为CT系统的临床应用和质量控制提供参考依据。 Objective:To design a oval phantom to assess the image qualities when advanced scanning techniques were applied on X-ray computed tomography(CT)system.Methods:The produced oval phantom which was compatible with Catphan was scanned on 3 kinds of advanced scanning models,included automatic exposure control(AEC),low dose scan and dual energy scan,of CT scan system of 3 various brands,and the accuracy of CT value,homogeneity and slice thickness of images were measured.The measurement of the accuracy of dual energy decomposition was implemented on two CT scan systems which supported dual energy.Results:The image qualities of the oval phantom that was measured under variously advanced scanning model didn't have obvious decline,and they could meet the national mandatory standard for image quality.And the accuracy of material decomposition of dual energy scanning of CT scan system was within±20%.Conclusion:The oval phantom can implement quality assessment for image under advanced scanning technique of CT system,and it can provided references for clinical application and quality control of CT system.
作者 周锡明 王禹鑫 张弛 任烨 蔡彪 ZHOU Xi-ming;WANG Yu-xin;ZHANG Chi(The Center of Medical Engineering,The First People's Hospital of Yueyang,Yueyang 414000,China)
出处 《中国医学装备》 2019年第9期23-27,共5页 China Medical Equipment
基金 国家卫计委能力建设和继续教育中心课题(JJJX20180001 KT)“医院器械管理能力建设体系研究”
关键词 CT系统 图像质量 高级扫描技术 低剂量扫描 自动曝光控制 双能 X-ray computed tomography(CT)system Image quality Advanced scanning techniques Low dose scan Automatic exposure control(AEC) Dual energy
  • 相关文献

参考文献3

二级参考文献16

  • 1李旭超,朱善安.图像分割中的马尔可夫随机场方法综述[J].中国图象图形学报,2007,12(5):789-798. 被引量:64
  • 2杨春玲,陈冠豪,谢胜利.基于梯度信息的图像质量评判方法的研究[J].电子学报,2007,35(7):1313-1317. 被引量:62
  • 3Nevzat Karabulut,Mustafa T?rü,Veli Gelebek,Meltem Gülsün,Macit O. Ariyürek. Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules[J] 2002,European Radiology(11):2764~2769
  • 4M. Gartenschl?ger,F. Schweden,K. Gast,T. Westermeier,H.-U. Kauczor,H. von Zitzewitz,M. Thelen. Pulmonary nodules: detection with low-dose vs conventional-dose spiral CT[J] 1998,European Radiology(4):609~614
  • 5WANG Zhou, Bovik AC. Mean squared error.. Love it or leave it? A new look at signal fidelity measures[J]. IEEE Signal Processing Magazine, 2009, 26 (1): 98-117.
  • 6Hore A, Ziou D. Image quality metrics: PSNR vs. SSIM [C] //20th International Conference on Pattern Recognition, 2010: 2366-2369.
  • 7LI Chaoeng, Bovlk AC. Content-partitioned structural simi- larity index for image quality assessment [J]. Signal Proce- ssing: Image Communication, 2010, 25 (7): 517-526.
  • 8Narravula SR, Hayat MM, Javidi B. Information theoretic ap- proach for assessing image fidelity in photon-counting arrays [J]. Opties Express, 2010, 18 (3): 2449-2466.
  • 9Soundararajan R, Bovik AC. RRED indices: Reduced reference entropic differencing for image quality assessment [ J ]. IEEE Transactions on lmageProcessing, 2012, 21 (2): 517-526.
  • 10Chen MJ, Bovik AC. Fast structural similarity index algo- rithm [J].Journal of Real-Time Image Processing, 2011, 6: 281-287.