期刊文献+

全机静力试验一体化加载框架设计技术研究 被引量:3

Research on Design Technology of Integrated Loading Frame for Full-Scaled Static Test
下载PDF
导出
摘要 为满足全机静力试验加载、测控以及检查的需求,在国内静力试验中首次采用钢架结构的框架设计技术,参照建筑钢构形式及相应的设计规范,提出一体化框架设计技术,并提出了一套可行、通用的一体化框架设计规程,为后续一体化框架设计提供参考。 In order to meet the requirements of load,measure and controll and inspection in the static test of large transport aircraft,the frame design technology of steel frame structure was first adopted in the domestic static test.Referring to the form of building steel structure and the corresponding design specifications,an integrated frame design technology was put forward,and a feasible and universal integrated frame design specification was put forward,which provided a reference for the follow-up integrated frame design.
作者 杨鹏飞 Yang Pengfei(Full Scale Aircraft Structure Static/Fatigue Laboratory of Aircraft Strength Research Institute of China,Xi'an Shaanxi 710065,China)
出处 《工程与试验》 2019年第2期128-130,共3页 Engineering and Test
关键词 一体化加载框架 钢架结构 设计规程 integrated loading frame steel frame structure design specification
  • 相关文献

参考文献3

二级参考文献19

  • 1武振宇,张耀春.直接焊接钢管节点静力工作性能的研究现状[J].哈尔滨建筑大学学报,1996,29(6):102-109. 被引量:34
  • 2鲁琛.空间直接焊接圆钢管节点足尺试验研究,硕士学位论文[M].同济大学,2000..
  • 3同济大学钢结构研究室.成都双流机场扩建工程航站楼钢结构屋盖结构试验研究与分析--相贯节点试验报告[M].,2000..
  • 4张志良.焊接方管节点极限承载力的试验研究和非线性有限元分析,硕士学位论文[M].同济大学,1988..
  • 5刘鹏.方圆汇交平面钢管节点的刚度研究,硕士学位论文[M].同济大学,2001..
  • 6Packer J A 等 曹俊杰(译).空心管结构连接设计指南[M].科学出版社,1997..
  • 7Zhen Chen. Experimental Research on Full-Scall Multiplanar CHS Joints.In: Candidacy for the Master of Engineering Science. 2002.14.
  • 8岡本舜三.钢构造の研究[M].技报堂出版社,昭和52年..
  • 9东北工学院机械设计 机械制图教研室.机械零件设计手册[M].北京:冶金工业出版社,1973.126-159.
  • 10彼德逊RE 刘纯朴 译.设计中的应力集中系数[M].北京:中国工业出版社,1965.112,113.