摘要
目的:总结在X线透视引导下气道瘘封堵覆膜金属内支架取出术的应用效果。方法:85例患者共放置90枚气道覆膜金属内支架用于封堵气道瘘,在X线透视引导下取出支架,其中男72例,女13例,年龄15~81(54.9±12.3)岁。回顾患者临床资料,分析支架取出的适应证。结果:85例患者90枚支架,成功取出89枚,技术成功率98.9%;仅1枚支架存在金属丝残留,经支气管镜成功取出;支架取出操作时间为(19.0±8.6)min。取出原因:常规取出46例,支架移位11例,肉芽组织过度增生10例,气道瘘复发8例,支架不耐受6例,支架断裂4例,留置时间分别为97.5(76.5,123.0)、11.0(3.0,26.0)、119.5(90.8,219.8)、24.0(10.0,64.0)、5.5(2.3,10.3)和89.5(74.0,127.5)d。支架取出术的并发症有支架金属丝残留(1例)、气道黏膜撕裂伴大咯血(2例)、因气道再狭窄需再次置入支架(1例)、需要机械通气的呼吸困难(1例)、吸氧可缓解的呼吸困难(1例)。结论:在X线透视引导下取出用于封堵气道瘘的覆膜金属内支架安全、有效;推荐支架取出的时间窗为置入后第31~90天。
Aim:To investigate the indications and complications of X-ray fluoroscopy-guided removal of covered metal stent for blocking airway fistulas.Method:A total of 85 patients(72 males and 13 females)with airway fistulas were treated with 90 covered metal stents,and the stents were removed under the guidance of X-ray fluoroscopy.The age of the patients was 15 to 81(54.9±12.3)years.The clinical data of the patients were reviewed and the indications and complications of stent removal were analyzed.Results:A total of 89 stents were successfully removed,and the technical successful rate was 98.9%.Only one stent with residual metal wires was removed by bronchoscope.The time of stent removal was(19.0±8.6)min.The reasons for removal were as follows:conventional removal in 46 cases,stent displacement in 11 cases,excessive granulation tissue hyperplasia in 10 cases,airway fistula recurrence in 8 cases,stent intolerance in 6 cases,stent rupture in 4 cases,and the retention time was 97.5(76.5,123.0),11.0(3.0,26.0),119.5(90.0,219.8),24.0(10.0,64.0),5.5(2.3,10.3)and 89.5(74.0,127.5)days,respectively.The complications of stent removal included residual metal wire(1 case),airway mucosal tear with massive hemoptysis(2 cases),re-stenting due to airway restenosis(1 case),and dyspnea requiring mechanical ventilation(1 case),dyspnea relieved by oxygen(1 case).Conclusion:X-ray fluoroscopic removal of airway stent for blocking airway fistulas is safe and effective.The recommended removal time window is 31 to 90 days after the stent implantation.
作者
毕永华
伊梦飞
付培基
吴刚
任建庄
路慧彬
任克伟
韩新巍
BI Yonghua;YIN Mengfei;FU Peiji;WU Gang;REN Jianzhuang;LU Huibin;REN Kewei;HAN Xinwei(Department of Interventional Radiology,the First Affiliated Hospital,Zhengzhou University,Zhengzhou 450052)
出处
《郑州大学学报(医学版)》
CAS
北大核心
2019年第5期650-653,共4页
Journal of Zhengzhou University(Medical Sciences)
基金
国家自然科学基金项目(81501569)
关键词
气道内支架
气道瘘
X线透视引导
支架取出
airway stent
airway fistula
X-ray fluoroscopy guidance
removal of stent