期刊文献+

Recent progress of nanogenerators acting as biomedical sensors in vivo 被引量:11

Recent progress of nanogenerators acting as biomedical sensors in vivo
原文传递
导出
摘要 Since the nanogenerator(NG) was invented in 2006, it has been successfully developed and utilized to harvest various forms of mechanical energy in vivo. The NGs promote the progress of self-powered biomedical devices. Moreover, NGs can also be used as sensors to detect a variety of important physiological signals, which brings us closer to real-time, high-fidelity monitoring of physical and pathological information. This paper summarizes the in vivo applications of NGs as biomedical sensors, including in cardiac sensors, respiration sensors, blood pressure sensors, gastrointestinal sensors and bladder sensors.However, there are still many challenges in using NGs as sensors in vivo. For example, how can we minimize and encapsulate the NGs, how can we increase the stability and reliability during long-term detection, and how can we establish a corresponding relationship between the NG’s electrical output and the physiological signals. It is also critical to follow the medical principles more closely in the development of self-powered sensors in the future. We believe that the self-powered sensors would promote the development of the next-generation healthcare monitoring systems. Since the nanogenerator(NG) was invented in 2006, it has been successfully developed and utilized to harvest various forms of mechanical energy in vivo. The NGs promote the progress of self-powered biomedical devices. Moreover, NGs can also be used as sensors to detect a variety of important physiological signals, which brings us closer to real-time, high-fidelity monitoring of physical and pathological information. This paper summarizes the in vivo applications of NGs as biomedical sensors, including in cardiac sensors, respiration sensors, blood pressure sensors, gastrointestinal sensors and bladder sensors.However, there are still many challenges in using NGs as sensors in vivo. For example, how can we minimize and encapsulate the NGs, how can we increase the stability and reliability during long-term detection, and how can we establish a corresponding relationship between the NG’s electrical output and the physiological signals. It is also critical to follow the medical principles more closely in the development of self-powered sensors in the future. We believe that the self-powered sensors would promote the development of the next-generation healthcare monitoring systems.
出处 《Science Bulletin》 SCIE EI CAS CSCD 2019年第18期1336-1347,共12页 科学通报(英文版)
基金 supported by the National Key Research and Development Program of China (2016YFA0202703) the Scientific Research Foundation for Advanced Scholars of Foshan University (Gg07136, Gg07164) the Key Platform and Scientific Research Project of Guangdong Provincial Education Department (2018KTSCX246) the Science and Technology Planning Project of Guangdong Province (2018B030331001) the National Natural Science Foundation of China (61875015, 31571006, 81570202, and 8157037) the Beijing Natural Science Foundation (2182091) the National Youth Talent Support Program
关键词 NANOGENERATOR IMPLANTABLE device BIOMEDICAL sensor In VIVO Nanogenerator Implantable device Biomedical sensor In vivo
  • 相关文献

参考文献3

二级参考文献22

  • 1张清友,杜军保,李万镇,王喻丽.米多君治疗儿童血管迷走性晕厥疗效观察[J].中国实用儿科杂志,2006,21(11):826-828. 被引量:35
  • 2CHEN Li,YANG Yuan-yuan,WANG Cheng,WANG Hong-wei,TIAN Hong,ZHANG Qing-you,CHEN Jian-jun,WANG Yu-li,KANG Yi-long,TANG Chao-shu,DU Jun-bao.A multi-center study of hemodynamic characteristics exhibited by children with unexplained syncope[J].Chinese Medical Journal,2006(24):2062-2068. 被引量:23
  • 3张清友,杜军保,甄京兰,李万镇,王喻丽.血管迷走性晕厥儿童在直立倾斜试验中血流动力学变化及其对美托洛尔疗效的预测[J].中华医学杂志,2007,87(18):1260-1262. 被引量:26
  • 4Chang FK (1998) Structural health monitoring: current status and perspectives. CRC Press, Boca Raton.
  • 5Mufti AA (2001) Guidelines for structural health monitoring. Canada Research Network for Intelligent Sensing for Innovative Structures, Winnipeg.
  • 6Ou JP, Li H, Duan ZD (2006) Structural health monitoring and intelligent infrastructure. Taylor & Francis, London.
  • 7Xu YL, Xia Y (2012) Structural health monitoring of long-span suspension bridges. CRC Press, Boca Raton.
  • 8Aktan A, Catbas F, Grimmelsman K et al (2000) Issues in infras- tructure health monitoring for management. J Eng Mech 126:711-724.
  • 9Brownjohn JM, Pan TC (2008) Identifying loading and response mechanisms from ten years of performance monitoring of a tall building. J Perform Constr Facil 22:24-34.
  • 10Xu Y (2008) Making good use of structual health monitoring systems: Hong Kong's experience. In: Proceedings of the second international forum on advances in structural engineering, structual disaster prevention, monitoring and control, Hongnan LI & Tin- ghua Yi, China Architeture & Building Press, Beijing, pp 159-158.

共引文献70

同被引文献39

引证文献11

二级引证文献57

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部