期刊文献+

正畸治疗中微螺钉支抗的稳定性研究

下载PDF
导出
摘要 目的研究正畸治疗中微螺钉支抗的稳定性。方法选取15例患者为研究对象,共种植微螺钉36颗,通过评价种植数量、种植位置、种植位置的反应、种植力度、加力时间、患者口腔卫生等临床变量并结合SPSS 19.0软件分析技术来确定影响微螺钉支抗稳定性的因素。结果在36颗微螺钉中,33颗微螺钉种植成功,成功率为91.7%。患者治疗时,种植部位不同,微螺钉的稳定性不同;若在种植早期施加种植力度,则会影响正畸治疗,若在后期加大种植力度,则对治疗无显著影响;口腔卫生良好的患者,其治疗效果及微螺钉的稳定性更加显著,而其他变量则对治疗效果影响不大。结论种植部位、治疗初期的稳定性及患者口腔卫生情况是影响微螺钉支抗稳定性的重要因素。
作者 王焱
出处 《全科口腔医学电子杂志》 2019年第31期31-31,37,共2页 Electronic Journal of General Stomatology
  • 相关文献

参考文献1

二级参考文献31

  • 1Roberts WE, Helm FR, Marshall KJ, et al. Rigid endosseous implants for orthodontic and orthopedic anchorage [J]. Angle Orthod, 1989, 59(4): 247-256.
  • 2Kanomi R. Mini-implant for orthodontic anchorage [J]. J Clin Orthod, 1997, 31(11): 763-767.
  • 3Kuroda S, Sugawara Y, Deguchi T, et al. Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative disconffort [J]. Am J Orthod Dentofacial Orthop, 2007, 131(1): 9-15.
  • 4Herman RJ, Currier GF, Miyake A. Mini-implant anchorage for maxillary canine retraction: a pilot study [J]. Am J Orthod Dentofacial Orthop, 2006, 130(2): 228-235.
  • 5Chen Y, Shin HI, Kyung HM. Biomechanical and histological comparison of self-drilling and self-tapping orthodontic microimplants in dogs[J]. Am J Orthod Dentofacial Orthop, 2008, 133(1): 44-50.
  • 6Wiechmann D, Meyer U, Btichter A. Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study[J]. Clin Oral Implants Res, 2007, 18(2): 263-267.
  • 7Chen YJ, Chang HI-I, Huang CY, et al. A retrospective analysis of the failure rate of three different orthodontic skeletal anchorage systems[J]. Clin Oral Implants Res, 2007, 18(6): 768-775.
  • 8Park HS, Jeong SH, Kwon OW. Factors affecting the clinical success of screw implants used as orthodontic anchorage[J]. Am J Orthod Dentofacial Orthop, 2006, 130(1): 18-25.
  • 9Miyawaki S, Koyama I, Inoue the stability of titanium screws orthodontic anchorage[J]. Am J 124(4): 373-378 M, et al. Factors associated with placed in the posterior region for Orthod Dentofacial Orthop, 2003,.
  • 10Motoyoshi M, Yoshida T, Ono A, et al. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants [J]. Int J Oral Maxillofac Implants, 2007, 22(5): 779-784.

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;