根据国家相关规范要求,介绍了余压监控系统的设计及应用,提出余压监控系统可有效解决疏散门两侧压差过大而导致防火门无法正常开启的问题,保证疏散通道的安全畅通,为火灾情况下人员疏散和营救提供有力的保障。
According to the relevant national standards,the design and application of residual pressure monitoring system was introduced.The residual pressure monitoring system can effectively solve the problem that the fire door cannot be opened normally due to the excessive pressure difference on both sides of the evacuation door,and ensures the safe and open evacuation exit.It can provide a strong guarantee of evacuation and rescue in case of fire.
作者
吴荡儒
WU Dangru(Zhuhai Pilot Technology Co.,Ltd.,Zhuhai 519085,China)
出处
《现代建筑电气》
2019年第9期42-43,49,共3页
Modern Architecture Electric
关键词
余压监控系统
余压探测器
余压控制器
系统结构
residual pressure monitoring system
residual pressure detector
residual pressure controller
system structure