期刊文献+

塑封器件分层检测不合格原因探讨 被引量:3

Unqualified Analysis about Delamination Testing of the Plastic Encapsulated Microcircuit
下载PDF
导出
摘要 在塑封半导体器件内部裂纹、空洞和分层缺陷的检测中,同样的样品不同单位、不同试验人员总会出现一些器件检测结果不一致的情况。为研究导致检测结果不一致的原因,通过对超声扫描检测技术原理和适用判据标准的阐述,对不同设备的比对验证以及对塑封器件材料的吸湿影响试验和分析,探讨了塑封器件分层检测不合格和不一致的原因,为同行业者提供借鉴和参考。 Acoustic scanning microscope is an important equipment for plastic encapsulated microcircuit(PEM)on testing the internal cracks,voids and delaminations.In practical work,the testing results will be different,because of the marginal influence such as the material absorption humidity,equipment set status or different defects criterion etc.The principle of the acoustic scanning technology,proper standard and defects criterion are stated.The influence from the different equipment status and material absorption humidity are analyzed.The unqualified and inconsistent reasons in the testing of the PEM,so as to get the more reliable and more precise result on the judging the delamination defects of the PEM are summarized for your reference.
作者 马清桃 王伯淳 王瑞崧 MA Qingtao;WANG Bochun;WANG Ruisong(The 4th Institute Components Reliability Sub-Centers of China Aerospace Science&Industry Corp.,Xiaogan 432000,China)
出处 《电子与封装》 2019年第10期13-16,48,共5页 Electronics & Packaging
关键词 塑封器件 缺陷判断 材料吸湿 plastic encapsulated microcircuit defects criterion material absorption humidity
  • 相关文献

参考文献4

二级参考文献18

  • 1肖培义,李基森,卢艺森,陈杰.超声波探伤技术在MLCC检测中的应用研究[J].电子质量,2006(7):18-20. 被引量:5
  • 2张鹏,陈亿裕.塑封器件失效机理及其快速评估技术研究[J].半导体技术,2006,31(9):676-679. 被引量:27
  • 3吴时红,何双起.超声显微检测技术的应用研究[J].无损检测,2007,29(5):278-279. 被引量:8
  • 4ADAMS T. Acoustic inspection of square-section capacitors [J].Passive Component Industry, 2007, (1/2) :33-34.
  • 5J. Crank. The Mathematics of Diffusion 2^nd Edition, [C]. Clarendon Press, Oxford, UK, 1975.
  • 6X. Chen, S.F. Zhao, L. Zhai. Moisture absorption and diffusion characterization of molding compound[J]. ASME J. Electronic Packaging; Vol. 127, No. 4, 2005, pp: 460-465.
  • 7E.H. Wong, R. Rajoo.Moisture absorption and diffusion characterization of packaging materials-advanced treatment[J].Microelectronics Reliability, Vol. 43, 2003, pp: 2087-2096.
  • 8S.F. Zhao, X. Chen, J.Z. Yao.Impact of Hygroswelling and Vapor Pressure on Delamination [J]. IEEE Proceeding 8th Electronics Packaging Technology Conference, 2006, pp: 774-781.
  • 9A. Nishimura, I. Hirose, N. Tanaka.A new method for measuring adhesion strength of IC molding compounds [J].ASME J. Electronic Packaging, Vol. 114, 1992, pp:407-412.
  • 10H.A. Richard, K. Benitz.A loading device for the creation of mixed mode fracture mechanics [J].Int. J. Fracture, Vol. 22, 1983, pp: R55-R58.