期刊文献+

1000 MW机组烟风管道优化的分析及效果 被引量:4

Analysis and Effect of Flue Gas Pipeline Optimization for 1 000 MW Unit
下载PDF
导出
摘要 为了比较矩形烟风道与圆形烟风道优劣,以安徽某电厂二期扩建工程2×1 000 MW机组为对象,通过具体计算比较,采用圆形烟风道每台锅炉节省烟风道耗材共119.81 t,2台锅炉共节省239.62 t,钢材按1万/t来计算,每台锅炉可节省119.81万元,2台锅炉共节省239.62万元。 In order to compare the advantages and disadvantages of rectangular flue duct and circular flue duct,taking 2×1 000 MW units in the second phase e×pansion project of a power plant in Anhui Province as the object,through specific calculation and comparison,the consumption of material in flue duct for each boiler with circular flue duct is 119.81 t,the consumption of material for two boilers is 239.62 t,and steel is calculated by 10,000 t.The savings of each boiler can be 11.981 million yuan,and 2 boilers can be 239.620 million yuan.
作者 吴志祥 WU Zhixiang(Anqing Wanjiang Power Generation Co.,Ltd.,Anqing 246000,China)
出处 《锅炉技术》 北大核心 2019年第5期37-41,共5页 Boiler Technology
关键词 矩形烟风道 圆形烟风道 优化 分析 效果 rectangular flue duct circular flue duct optimization analysis effect