摘要
针对D类干粉灭火系统误喷,结合烷基铝火灾的特点和D类干粉系统对火灾的检测情况,通过对D类干粉灭火系统检测原理、系统设计、系统组成、周边硬件设施和日常维护操作等几个方面进行说明和改进,从而提升D类干粉灭火系统的抗干扰性。
In view of the action for D-class dry powder fire extinguishing system misoperation,Combining with the characteristics of the alkyl aluminium fire and D-class dry powder system to detect fire situation,detection principle of D-class dry powder fire extinguishing system,the principle,design,composition,hardware facilities and daily maintenance operation and some other characteristicscs of D-class dry powder fire extinguishing system were elaborated in dedetail,which was expected to provide experience and guidance for D-class dry powder fire extinguishing system in anti-interference performance.
作者
盛利
Sheng Li(Zhejiang Petrochemical Co.,Ltd.,Zhoushan 316000)
出处
《石化技术》
CAS
2019年第9期1-2,共2页
Petrochemical Industry Technology
关键词
D类干粉灭火系统
烷基铝类火灾
红外火焰探测器
D-class dry powder fire extinguishing system
aluminum alkyls chemical related fire