期刊文献+

RO保安过滤器滤芯污堵分析及解决方案 被引量:2

Analysis of the Pollution Blockage in RO Security Filter Core and Solutions
下载PDF
导出
摘要 反渗透前5u保安过滤器主要是确保膜元件不受大颗粒物质的物理损坏,针对凌钢滤芯频繁污堵问题,论文对预处理工艺和后续工艺进行逐项排查,确定是保安过滤器处细菌再滋生造成的滤芯污堵,通过排除,分析出造成细菌滋生的原因,并采取相关措施使滤芯污堵问题得以解决。 Before reverse osmosis,the 5u security filter is mainly to ensure that the membrane elements are not physically damaged by large particles of material.Aiming at the problems of frequent pollution and blockage of the filter core of Ling Steel,the paper checked the pretreatment process and the follow-up process item by item,determined that the pollution and blockage of the filter core was caused by the bacteria re-breeding in the security filter.Through elimination,the paper analyzes the cause of bacteria breeding,and takes relevant measures to solve the problems of pollution and blockage of the filter core.
作者 张建辉 ZHANG Jian-hui(Lingyuan Iron&Steel Group Co.Ltd.,Chaoyang 122500,China)
出处 《中小企业管理与科技》 2019年第27期169-170,共2页 Management & Technology of SME
关键词 保安过滤器 还原剂 杀菌 security filter reducing agent sterilization
  • 相关文献

参考文献1

二级参考文献3

  • 1吕人豪.材料的微生物腐蚀[J].材料保护,1990,23(2):26-30.
  • 2[3] Gibson G R.Physiology and ecology of the sulfate-reducing bacteria[J]. Journal of Applied Bacteriology, 1990, 69(16):769797.
  • 3俞敦义,金永成,刘小武,彭芳明.硫酸盐还原菌的去极化作用[J].材料保护,1998,31(7):4-5. 被引量:3

共引文献29

同被引文献18

引证文献2

二级引证文献3