摘要 大型火电机组的给水泵并泵过程时间较长、操作复杂、手动操作具有一定的危险性。结合实际并泵中出现的问题,提出了自动并泵控制策略。通过在某电厂机组实际应用,证明了采用自动并泵控制策略后机组主要参数运行平稳,减轻了运行人员的操作强度,也提高了机组的自动化水平及可靠性。自动并泵逻存在的问题为后续的逻辑优化提供了方向。 Because of the long operation time,complex operation procedure and manual operation,there are risks in paralleling logic for feedwater pumps in large thermal power units.Automatic paralleling logic for feedwater pumps is proposed to address the difficulty in pump paralleling practice.Application in a power plant showed that main parameters of units were stable after taking automatic feedwater pump paralleling,which subsequently relieved operating strength of relevant personnel,as well as improved automation level and reliability of the unit.
作者 杨小龙 于国强 史毅越 殳建军 胡尊民 YANG Xiaolong;YU Guoqiang;SHI Yiyue;SHU Jianjun;HU Zunmin(Jiangsu Frontier Power Technology Company Limited,Nanjing 210000,China)
出处 《华电技术》 CAS 2019年第10期64-67,71,共5页 HUADIAN TECHNOLOGY
关键词 1000MW超超临界机组 给水泵 自动并泵 给水流量控制 1 000 MW supercritical unit feedwater pump automatic pump paralleling control of feedwater flow