摘要 某电厂给水在线pH表与便携式仪表测量偏差较大,核心化学仪表测量数据出现偏差会影响化学监督控制的准确性,机组长期运行可能会出现严重事故。详细分析了影响测量的各种因素,并提出了有效的解决方法。 The pH value of feed water measured by online water pH meter and portable water pH meter has a large deviation in a power plant.The deviation of the measurement data of the core chemical instrument will affect the accuracy of chemical supervision and control,Long-term operation of the unit may cause serious accidents.Analyzes the influencing reasons detailedly,and puts forward some effective settlements.
作者 李玉楠 Li Yu’nan(China Datang Corporation Science and Technology Research Institute Co.,LTD.,East China Electric Power Test&Research Institute,Hefei,230001,China)
出处 《仪器仪表用户》 2019年第12期97-99,共3页 Instrumentation
关键词 给水 PH 测量 feedwater pH meter measure
  • 相关文献

参考文献1

二级参考文献3

  • 1[1]O.Jonas.Combined Water Treatment Improves Boiler Reliability[J].Power, 1984,128(4):112.
  • 2[2]EPRI.Effect of Hydrazine and pH on Corrosion of CopperAlloy Materials in AVT Environments With Oxygen[R].EPRI NP2654,1982.
  • 3[3]VGBR 450,VGB Guidelines for Boiler Feedwater, Boiler Water and Steam of Steam Generators With a Permissible Operating Pressure >68 bar[S].1988.