Monte Carlo assessment of coded aperture tool for breast imaging: a Mura-mask case study 被引量:2

Monte Carlo assessment of coded aperture tool for breast imaging: a Mura-mask case study
下载PDF
导出
摘要 The main purpose of this work was to perform a rigorous computational study on scintimammography with a Mura-mask based on Monte Carlo simulation of voxelized breast phantoms. Three main objectives were addressed:(1) verification of Geant4 version 10.4,(2)optimization of the imaging setup, and(3) small tumor detection and localization. We successfully verified the Geant4-based imaging of a commonly used phantom in the field. We used a Mura-mask with a 41× 41 array pattern with adjustable thickness, material, and hole shape(box and cylinder);a low-energy high-resolution collimator with different hole shapes(cylinder and hexagon);and a voxelized breast phantom with different sizes(small, medium,and large) and glandularity percentages(low, medium, and high). We also compared the detector crystal outputs of CdZnTe and NaI(Tl). The simulation was followed by a deconvolution procedure, and the data(images) were statistically emphasized. Statistical metrics indicate that the Mura-mask(W material with 1.5 mm thickness and box holes) combined with a CdZnTe detector leads to the optimum point spread function. Finally, a preliminary study on small-sized tumor detection and localization was conducted with different tumor-to-background ratios(from2 to 12). Tumors with diameters of 5 and 8 mm could be detected, while those of 2 mm were undetectable. Nevertheless, this study enhances our understanding of the early detection of tumors in the field of scintimammography. The main purpose of this work was to perform a rigorous computational study on scintimammography with a Mura-mask based on Monte Carlo simulation of voxelized breast phantoms. Three main objectives were addressed:(1) verification of Geant4 version 10.4,(2)optimization of the imaging setup, and(3) small tumor detection and localization. We successfully verified the Geant4-based imaging of a commonly used phantom in the field. We used a Mura-mask with a 41 × 41 array pattern with adjustable thickness, material, and hole shape(box and cylinder); a low-energy high-resolution collimator with different hole shapes(cylinder and hexagon); and a voxelized breast phantom with different sizes(small, medium,and large) and glandularity percentages(low, medium, and high). We also compared the detector crystal outputs of CdZnTe and NaI(Tl). The simulation was followed by a deconvolution procedure, and the data(images) were statistically emphasized. Statistical metrics indicate that the Mura-mask(W material with 1.5 mm thickness and box holes) combined with a CdZnTe detector leads to the optimum point spread function. Finally, a preliminary study on small-sized tumor detection and localization was conducted with different tumor-to-background ratios(from2 to 12). Tumors with diameters of 5 and 8 mm could be detected, while those of 2 mm were undetectable. Nevertheless, this study enhances our understanding of the early detection of tumors in the field of scintimammography.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第11期10-20,共11页 核技术(英文)
基金 supported by The National Plan for Science,Technology and Innovation(MAARIFAH) King Abdulaziz City for Science and Technology,Kingdom of Saudi Arabia,Award Number(12-MED2516-02)
关键词 GEANT4 Voxelized BREAST PHANTOM SCINTIMAMMOGRAPHY Mura-mask Geant4 Voxelized breast phantom Scintimammography Mura-mask
  • 相关文献

同被引文献8

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部