期刊文献+

Retardation of an IGG gas flow along a mine drift due to condensation and temperature decrease 被引量:1

Retardation of an IGG gas flow along a mine drift due to condensation and temperature decrease
下载PDF
导出
摘要 The progress of the GAG gas flow in a conveyor drift is investigated.The output of a calculation model is evaluated and compared with experimental results from full-scale inertisation experiments.Expressions presenting the fastest and most extensive condensation of water resulted in well fitted arrival times of the GAG gas front.A common denominator for the two sets of expressions is that the type of flow is considered and thus better fitted to the actual flow situation.The model was further refined to include the surface roughness factor in the condensation calculations,which resulted in time lengths even closer to the measured time length.The measured rapid temperature increase at certain positions along the conveyor drift was found to fit well with the calculated GAG gas front arrival at the corresponding positions.The magnitude of the GAG flow was found to have a large impact on the arrival time of the GAG gas front.Knowing and understanding the GAG gas behaviour would increase the likelihood of successful inertisation of all or part of a mine. The progress of the GAG gas flow in a conveyor drift is investigated. The output of a calculation model is evaluated and compared with experimental results from full-scale inertisation experiments. Expressions presenting the fastest and most extensive condensation of water resulted in well fitted arrival times of the GAG gas front. A common denominator for the two sets of expressions is that the type of flow is considered and thus better fitted to the actual flow situation. The model was further refined to include the surface roughness factor in the condensation calculations, which resulted in time lengths even closer to the measured time length. The measured rapid temperature increase at certain positions along the conveyor drift was found to fit well with the calculated GAG gas front arrival at the corresponding positions.The magnitude of the GAG flow was found to have a large impact on the arrival time of the GAG gas front.Knowing and understanding the GAG gas behaviour would increase the likelihood of successful inertisation of all or part of a mine.
出处 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2019年第6期831-839,共9页 矿业科学技术学报(英文版)
关键词 GAG Inert GAS CONDENSATION Temperature DECREASE GAS velocity MINE DRIFT GAG Inert gas Condensation Temperature decrease Gas velocity Mine drift
  • 相关文献

参考文献1

二级参考文献12

  • 1Morla R, Balusu R, Tanguturi K. Optimum inertisation techniques for blasting gallery method, ln: Proceedings of 3rd International Workshop on Mine Hazard Prevention and Control. Brisbane; 2013. p. 97-105.
  • 2Morla R, Balusu R, Tanguturi K, Khannal M. Prediction and control of spontaneous combustion in thick coal seams. In: Proceedings of Underground Coal Operators Conference. Wollongong; 2013. p. 232-39.
  • 3Yarlagadda BR, Liu T, Reddy VB. Proactive strategies for prevention and control of fires in Bord and Pillar mines working in Thick coal seams. In: Proceedings of Underground Coal Operators Conference. Wollongong; 2011. p. 249-56.
  • 4Kumar RS, Sastry VR. Induced stress in blasting gallery panel during depillaring based on field instruction, lnt J Earth Sci Eng 2012;01:5-6.
  • 5Beamish B, Blazak DG. Hogarth LC, Jabouri I. R70 Relationships and their Interpretation at a mine site. In: Proceedings of Underground Coal Operators Conference, Wollongong, 2005. p. 183-86.
  • 6Beamish B, TheilerJ, SauratJ, LeviT. Commissioning adiabatic oven Testing an inter laboratory comparision. In: Proceedings of Underground Coal Operators Conference. Wollongong, 2014. p. 324-29.
  • 7Beamish B, Arisoy A. Effect of intrinsic coal properties on self-heating rates, ln: 12th U.S/North American Mine ventilation Symposium. Reno. 2008.
  • 8Beamish B. Laboratory-Scale assessment of hot spot development in bulk coal self-heating. In: Proceedings of 8th International Mine Ventilation Congress. Brisbane, 2005. p. 355-59.
  • 9MohalikN, Panigrahi D, Singh V, Singh R. Assessment of spontaneous heating of coal by differential scanning calorimetric technique. In: Proceedings of Underground Coal Operators Conference. Wollongong, 2009. p. 303-10.
  • 10Joel HF, Miloran P. Computational methods for fluid dynamics. Berlin: Springer-Verlag; 2001.