摘要 采用建筑能耗模拟软件EnergyPlus对夏热冬冷地区自然通风双层玻璃幕墙在五种运行模式下的温度和气流速度进行模拟分析。为验证模型的准确性,对某双层玻璃幕墙实验房在全年不同运行模式下进行实验测试研究,并将实验数据与模拟结果进行对比验证,发现温度和气流速度的模拟结果吻合程度较好,模拟值与实测值的误差较小,模型可靠性较高。 In this paper, the whole building energy simulation program EnergyPlus is used to simulate the temperature and velocity of double skin facade under five natural ventilation modes. To verify the accuracy of the model, a series of experiment were conducted under different natural ventilation mode of the double skin facade in Zhuzhou and then compared with simulation results. It show good agreement between simulation and experiment results, with 80% of matching degree in temperature and 75% in air velocity. The error between simulated results and measured value is small, and the model has high reliability.
作者 王志勇 王俊 卜晖 WANG Zhi-yong;WANG Jun;BU Hui(School of Civil Engineering,Hunan University of Technology)
出处 《建筑热能通风空调》 2019年第10期19-22,52,共5页 Building Energy & Environment
基金 湖南省自然科学基金资助项目(2017JJ4030) 湖南省研究生科研创新项目(CX2017B702)
关键词 双层玻璃幕墙 ENERGYPLUS 自然通风 数值模拟 实验验证 double skin facade EnergyPlus natural ventilation numerical simulation experimental verification