Assessment of Building External Wall Thermal Performance Based on Temperature Deviation Impact Factor under Discontinuous Radiant Heating

Assessment of Building External Wall Thermal Performance Based on Temperature Deviation Impact Factor under Discontinuous Radiant Heating
原文传递
导出
摘要 As the variation and timely meeting thermal environment requirement of indoor air temperature has a close relationship with the thermal performance of building external wall under discontinuous radiant heating condition, one appropriate assessment method or index for assessing the building external wall thermal performance is very necessary. In order to reasonably evaluate the thermal performance of external wall under discontinuous radiant heating condition and build the direct connections and interactions among the indoor air temperature, external wall inner surface temperature and outdoor air temperature, the first and second impact factors of temperature deviation were established, based on one mathematical model of room heat transfer. For one experimental room and four types of external walls under discontinuous radiant heating condition, both the influence of the external wall inner surface temperature deviation on the indoor air temperature and that of the outdoor air temperature deviation on the external wall inner surface temperature were determined effectively with the first and second impact factors of temperature deviation. In addition, favourable performance for the self-insulation and inner insulation walls were found, due to their superiority in effectively and timely improving the indoor thermal environment under discontinuous radiant heating condition. As the variation and timely meeting thermal environment requirement of indoor air temperature has a close relationship with the thermal performance of building external wall under discontinuous radiant heating condition, one appropriate assessment method or index for assessing the building external wall thermal performance is very necessary. In order to reasonably evaluate the thermal performance of external wall under discontinuous radiant heating condition and build the direct connections and interactions among the indoor air temperature, external wall inner surface temperature and outdoor air temperature, the first and second impact factors of temperature deviation were established, based on one mathematical model of room heat transfer. For one experimental room and four types of external walls under discontinuous radiant heating condition, both the influence of the external wall inner surface temperature deviation on the indoor air temperature and that of the outdoor air temperature deviation on the external wall inner surface temperature were determined effectively with the first and second impact factors of temperature deviation. In addition, favourable performance for the self-insulation and inner insulation walls were found, due to their superiority in effectively and timely improving the indoor thermal environment under discontinuous radiant heating condition.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2019年第6期1129-1140,共12页 热科学学报(英文版)
基金 financial support from the Huimin Project of Chengdu Science and Technology Grant No. 2015-HM01-00548-SF the National Nature Science Foundation of China under Grant No. 51308361 Science and Technology Plan Project in Sichuan province Grant No. 2014GZ0133
关键词 temperature deviation impact FACTOR BUILDING EXTERNAL WALL thermal performance DISCONTINUOUS radiant HEATING temperature deviation impact factor building external wall thermal performance discontinuous radiant heating
  • 相关文献

参考文献2

二级参考文献16

  • 1魏立峰,戴立生,杨强,等.基于地板辐射盘管试块散冷测试的研究[C]∥全国暖通空调制冷2010学术年会论文集,2010.
  • 2Koschenz M, Lel~mann B. Thermoaktive Bauteilsysteme tabs [ M ]. Zurich: EMPA Energiesysteme Haustechnik, 2000.
  • 3De Monte F. Transient heat conduction in a one- dimensional composite slab. A 'natural' analytic approach[J]. International Journal of Heat and Mass Transfer, 2000, 43(19) : 3607- 3619.
  • 4Lu X, Tervola P. Transient heat conduction in the composite slab-analytical method[J].. Journal of Physics A Mathematical and General, 2005, 38 (1) : 81-96.
  • 5Beck J V, Haji-Sheikh A, Amos D E, et al. Verification solution for partial heating o.f rectangular solids [J]. International Journal of Heat and Mass Transfer, 2004, 47(19/20) : 4243-4255.
  • 6Laouadi A. Development of a radiant heating andcooling model for building energy simulation software [J]. Building and Environment, 2004:, 39(4): 421- 431.
  • 7Weber T, J6hannesson G. An optimized RC-network for thermally activated building components [J]. Building and Environment, 2005, 40(1): 1-14.
  • 8Holopainen R, Tuomaala P, piippo J. Uneven gridding of thermal nodal networks in floor heating simulations [J]. Energy and Buildings, 2007, 39 (10) : 1107-1114.
  • 9Koschenz M, Dorer V. Interaction of an air system with concrete core conditioning [J]. Energy and Buildings, 1999, 30(2) : 139-145.
  • 10Olesen B W. Possibilities and limitations of radiant floor cooling [G]//ASHRAE Trans, 1997, 103(1).. 42- 48.