Development and Application of Evaluation Index System and Model for Existing Building Green-Retrofitting 被引量:1

Development and Application of Evaluation Index System and Model for Existing Building Green-Retrofitting
原文传递
导出
摘要 This paper establishes an evaluation index system for existing building green-retrofitting considering different building majors. The weights of indicators at different levels were determined by using decision-making analytic hierarchy process. According to fuzzy mathematics theory, indicators at different levels were taken into an evaluation factor set while three-star level, two-star level, one-star level and unqualified level were taken as the comment set to develop a fuzzy comprehensive evaluation model for the green retrofitting of existing buildings. Additionally, the evaluation system proposed by this paper and the national standard "Assessment standard for green building" GB/T 50378-2014 were used in the assessment of a certain office after green retrofitting as a case study. The case study indicates that the evaluation developed by this research are more applicable for green retrofitting of existing building, while the national standard "Assessment standard for green building" has limitations except for new building. This paper establishes an evaluation index system for existing building green-retrofitting considering different building majors. The weights of indicators at different levels were determined by using decision-making analytic hierarchy process. According to fuzzy mathematics theory, indicators at different levels were taken into an evaluation factor set while three-star level, two-star level, one-star level and unqualified level were taken as the comment set to develop a fuzzy comprehensive evaluation model for the green retrofitting of existing buildings. Additionally, the evaluation system proposed by this paper and the national standard "Assessment standard for green building" GB/T 50378-2014 were used in the assessment of a certain office after green retrofitting as a case study. The case study indicates that the evaluation developed by this research are more applicable for green retrofitting of existing building, while the national standard "Assessment standard for green building" has limitations except for new building.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2019年第6期1252-1261,共10页 热科学学报(英文版)
基金 supported by National Key R&D Program of China (No.2018YFC0704800) China: Urban-Scale Building Energy Efficiency and Renewable Energy Project (No.2-B-CS-017)
关键词 existing building green-retrofitting EVALUATION system ANALYTIC HIERARCHY process FUZZY EVALUATION model existing building green-retrofitting evaluation system analytic hierarchy process fuzzy evaluation model
  • 相关文献

参考文献2

二级参考文献67

共引文献51

同被引文献9

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部