摘要 目的使用间隔流动分析建立同时检测生活饮用水中挥収酚类与氰化物含量的方法。方法选用自动进样器和在线蒸馏系统,对标准样品和实际样品进行在线蒸馏分析,数据处理软件直接给出样品溶液中挥収酚及氰化物的质量浓度。结果挥収酚类与氰化物的校准曲线相关系数分别为0.9993和0.9998,挥収酚和氰化物的3水平加标回收率分别为86.3%~101%和89.0%~99.2%,相对标准偏差分别为2.9%~7.9%和1.6%~6.8%。与国标方法相比,结果基本一致。结论该方法操作简便快捷,具有高灵敏度和低检出限,减少手工操作带来的误差,适用于大批量生活饮用水样品中挥収酚类和氰化物的测定。 Objective To establish interval flow analysis method for simultaneous determination of volatile phenols and cyanide in drinking water. Methods The standard sample and actual sample were analyzed by using automatic sampler and on-line distillation system. The mass concentration of volatile phenol and cyanide in the sample solution was directly gave by the data processing software. Results The correlation coefficients of the calibration curves of volatile phenols and cyanide were 0.9993 and 0.9998, respectively. The recoveries of volatile phenols and cyanide of 3 different spiked levels were 86.3%-101%, 89.0%-99.2%, the relative standard deviations were 2.9%-7.9% and 1.6%-6.8%, respectively. Conclusion The method is simple and quick to operate, has high sensitivity and low detection limit, reduces the error caused by manual operation, and is suitabl e for the determination of volatile phenols and cyanide in large quantities of drinking water samples.
作者 陈慧玲 毛丽莎 许欣欣 吕昭颖 刘红河 CHEN Hui-Ling;MAO Li-Sha;XU Xin-Xin;LV Zhao-Ying;LIU Hong-He(Shenzhen Center for Disease Control and Prevention,Shenzhen 518000,China)
出处 《食品安全质量检测学报》 CAS 2019年第20期6997-7000,共4页 Journal of Food Safety and Quality
关键词 间隔流动分析法 挥发酚类 氰化物 生活饮用水 interval flow analysis volatile phenols cyanide drinking water
  • 相关文献

参考文献10

二级参考文献41

共引文献80

同被引文献29

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部