导出
摘要 研制了一款组合式钢板仓,配合通风导管使用,开展高水分稻谷就仓干燥试验,将初始水分含量为23.4%的稻谷降至13.5%(安全水分),且水分分层控制在0.3%/m粮层内,干燥后稻谷品质良好,单位能耗为2.9 kW·h/(t·1%). In this paper,a composite steel bin was developed and used together with the ventilation tube to conduct the drying test of high-moisture paddy.The initial moisture content of 23.4%was successfully reduced to 13.5% which is the local safe moisture,and the moisture stratification was controlled within 0.3% per meter.The paddy after drying had good quality,and the unit energy consumption was 2.9 kW·h/(t·1%).
作者 曹胜男 刘超 周健 王懿 王万银 曹磊 顾广东 宋玉 段依梦 吴先山 朱昌保 Cao Shengnan;Liu Chao;Zhou Jian;Wang Yi;Wang Wanyin;Cao Lei;Gu Guangdong;Song Yu;Duan Yimeng;Wu Xianshan;Zhu Changbao(Anhui Institute of Grain and Oil Science,230031;Institute of Agricultural Products Processing,Anhui Accdemy of Agricultural Sciences,230001;Hefei Hongen Mechanicel and Electricel Technology Co.,Ltd.,230088)
出处 《粮食储藏》 2019年第5期1-4,共4页 Grain Storage
基金 安徽省科技重大专项项目(18030701148)
关键词 稻谷 就仓干燥 粮食品质 能耗 paddy dry-in-bin grain quality energy consumption