摘要
本文以中国河北沽源双馈-直驱混合风电场2016年发生的次同步振荡事件为例,基于现场实测数据分析了次同步振荡特性及影响因素,并在理论上建立了双馈-直驱混合风电场小信号数学模型。通过振荡模态和相关因子分析,探究了混合风电场中影响次同步振荡的因素并对其进行了仿真验证。理论分析和仿真结果表明,风电场中双馈与直驱风机的比例、串联补偿水平以及风力发电机变流控制器参数等是影响次同步振荡的重要因素,且在不同的风机比例下起主要作用的影响因素不同。
In this study,taking the sub-synchronous oscillation event that occurred in Guyuan hybrid wind farm of Hebei Province,China,in 2016 as an example,the characteristics and influencing factors of the sub-synchronous oscillation are analyzed in detail based on the field measured data.This paper builds a small signal mathematical model of DFIG-PMSG hybrid wind farm in theory,and through the modal analysis and correlation factor analysis,the influencing factors of sub-synchronous oscillation in hybrid wind farm are explored and verified in simulation.Theoretical analysis and simulation results show that the proportions of wind farm,series-compensated degree,controller parameters of wind turbine and power grid strength are important factors on sub-synchronous oscillation and the main influencing factors are different under the different proportion of wind farm.
作者
辛建波
舒展
赵诗萌
程思萌
徐衍会
XIN Jian-bo;SHU Zhan;ZHAO Shi-meng;CHENG Si-meng;XU Yan-hui(Electric Power Research Institute,State Grid Jiangxi Electric Power Company,Nanchang 330096,China;School of Electrical and Electronic Engineering,North China Electric Power University,Beijing 102206,China)
出处
《电工电能新技术》
CSCD
北大核心
2019年第11期24-32,共9页
Advanced Technology of Electrical Engineering and Energy
关键词
混合风电场
次同步振荡
风机比例
控制器参数
小信号分析
hybrid wind farm
sub-synchronous oscillation
proportion of wind farm
controller parameters
small-signal analysis