期刊文献+

10kV配电线路设备常见故障及应对对策探讨

Discussion on Common Faults of 10 kV Distribution Line Equipment and Countermeasures
下载PDF
导出
摘要 本文以10 kV配电线路设备常见故障为切入点展开具体分析,并提出强化导线接头的温度检测力度、及时检查绝缘子质量、增加变电所线路开关保护时间、安装避雷针并定期对其进行检查或更换等几方面的应对措施。注重分析10 kV配电线路设备产生故障的原因,并及时采取应对措施,最大程度上促进电力系统正常运行。 Based on the analysis of the common faults of 10 kV distribution line equipment,this paper puts forward some suggestions,such as strengthening the temperature detection of conductor joints,timely checking the quality of insulators,increasing the protection time of substation line switches,installing lightning rods and periodically checking or replacing them.Measures.It is hoped that in the normal operation of the power system in the future,we can focus on the analysis of the causes of failure of 10 kV distribution line equipment and take timely measures to promote the normal operation of the power system to the greatest extent.
作者 吴悠 Wu You
出处 《电力系统装备》 2019年第19期157-157,159,共2页 Electric Power System Equipment
关键词 10 KV配电线路 电力系统 常见故障 应对对策 10 kV distribution line power system common faults countermeasures