摘要
文章通过对山洪沟道流量测验中,使用斯德克电波流速仪(SVR-V2.0)和浮标法同时比测水面流速,对比分析结果表明,斯德克电波流速仪与浮标法同步施测的水体表面流速相对误差符合水文测验规范中对流速测验的要求,因此电波流速仪的稳定性和实用性得到验证,解决了韩府湾水文站中高水流速测验的难题。
In this paper,in the flow measurement of mountain torrent channel,the velocity of water surface is measured by Stalker PROⅡSVR-V2.0 and buoy method at the same time.The results show that the velocity of water surface is measured at the same time.The relative error of the surface velocity of water measured synchronously by the Stalker PROⅡSVR-V2.0 and the buoy method meets the requirements of the hydrological test specification for the velocity measurement,so the stability and practicability of the radio wave velocimeter have been verified.Thus,the difficult problem of medium and high water velocity measurement in Hanfuwan Hydrologic Station is solved.
出处
《科技创新与应用》
2019年第36期184-186,共3页
Technology Innovation and Application
关键词
斯德克电波流速仪
韩府湾水文站
比测应用分析
Stalker PROⅡSVR-V2.0
Hanfuwan Hydrological Station
comparison and application analysis