期刊文献+

便携气相色谱现场快速测定固定污染源废气中的非甲烷总烃 被引量:2

Rapid determination of non-methane hydrocarbon from stationary source emission by portable gas chromatography
下载PDF
导出
摘要 利用便携式气相色谱技术,建立了固定污染源废气中非甲烷总烃(NMHC)的现场快速测定方法。方法检出限为总烃0.07 mg/m ^3,甲烷0.06 mg/m ^3,NMHC 0.07 mg/m^ 3。该方法操作简单,用时短,检测结果准确可靠,适用于固定污染源NMHC的现场快速测定。 A rapid on-site method for the determination of non-methane total hydrocarbons(NMHC)from stationary source emission was established by using portable gas chromatography.The detection limits were 0.07 mg/m ^3 for total hydrocarbons,0.06 mg/m^ 3 for methane and 0.07 mg/m^ 3 for NMHC.The method is simple,time-consuming,accurate and reliable.It is suitable for rapid determination of NMHC from stationary source emission.
作者 马超 MA Chao(Xinjiang Ecological Environment Monitoring Centre,Urumqi Xinjiang 830011,China)
出处 《干旱环境监测》 2019年第4期171-173,共3页 Arid Environmental Monitoring
关键词 便携气相色谱 固定污染源 非甲烷总烃(NMHC) portable gas chromatography stationary source emission non-methane hydrocarbon(NMHC)
  • 相关文献

参考文献3

二级参考文献42

共引文献121

同被引文献22

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部