以杭州中润中心工程为例,通过分析该高层建筑地下室渗漏的原因。针对建筑物出现的不同渗漏情况从埋管压浆、混凝土空洞部位、堵漏三个方面的具体治理施工进行了详细阐述。
Taking Zhongrun center project in Hangzhou as an example, the reason of basement leakage of the high-rise building is analyzed. According to the different leakage situation of the building, this paper expounds the concrete treatment construction from three aspects:pipe grouting, concrete cavity position and leakage stoppage.