定子绕组匝间短路为永磁同步曳引机的一种常见故障,严重影响电梯正常运行。本文分析电动机匝间短路产生的原因,描述匝间短路时电梯的表现特征,总结出电梯温度、电流、噪声、运行平稳度等的综合现象来判定电梯的匝间短路故障,结合实际案例分析电梯曳引机定子绕组匝间短路故障。
The stator winding Inter-turn short circuit fault of permanent magnet synchronous traction machine is a common problem,which seriously affects the normal operation of the elevator.In this paper,the causes of interturn short circuit of motor are analyzed,and the performance characteristics of elevator during turn-to-turn short circuit are described.It summarizes the comprehensive phenomena of elevator temperature,current,noise and running stability to judge the inter-turn short circuit fault of elevator.At last,it analyzes inter-turn short circuit fault in stator winding of elevator traction machine based on practical cases.
作者
李文明
李文鹏
雷磊
王平坚
Li Wenming;Li Wenpeng;Lei Lei;Wang Pingjian(Chengdu Special Equipment Inspection Institute,Chengdu,610036)
出处
《中国特种设备安全》
2019年第10期56-58,62,共4页
China Special Equipment Safety
关键词
匝间短路
温度
电流
噪声
运行平稳度
Inter-turn short circuit
Temperature
Current
Noise
Running stability