摘要 渤海湾某油田生产水处理系统絮凝剂注入管线为铜镍合金材质,自2013年投运后铜镍合金主管线发生多次腐蚀渗漏问题,导致生产污水系统运行不稳定,严重影响注水水质。运用滴定法对生产水中离子进行分析,利用腐蚀原理得出了铜镍合金腐蚀原因,提出了几个改造方案,选择了适合絮凝剂注入的PPR材质管线。絮凝剂注入主管线渗漏问题在现场得以解决。 The material characteristic of the floccuant injection pipeline was Cu-Ni alloy which was used for the production oily water system of BO-HAI bay X oilfield,that had happened serious leakage problem since it was put into practiced in 2013.Resulting the production oily water system running unstable,seriously affected the quality of the production oily water system.By using the titration method to analysis the ion of the production oily water and using the corrosion theory,came up with cause of the corrosion of the Cu-Ni alloy,by giving serious projects,electing the project of using the PPR pipeline instead of the Cu-Ni alloy,the leakage problem of the floccuant agent pipeline was solved.
作者 柯文超 芦新辉 赵德喜 KE Wen-chao;LU Xin-hui;ZHAO De-xi(CNOOC China Co.,Ltd.Tianjin 300459,China)
出处 《全面腐蚀控制》 2019年第11期28-30,43,共4页 Total Corrosion Control
关键词 絮凝剂 铜镍合金 腐蚀原理 PPR管线 floccuant agent cu-nialloy corrosion theory PPR pipeline
  • 相关文献

参考文献4

二级参考文献17

  • 1刘伟华,曹中秋,郑志国.Cl^-含量对铸态Cu-40Ni合金电化学腐蚀行为的影响[J].沈阳师范大学学报(自然科学版),2004,22(3):220-223. 被引量:6
  • 2曹楚南.腐蚀电化学[M].北京:化学工业出版社,1994.133-133.
  • 3[1]Reza javaherdashti, A review of some characteristics of MIC caused by sulfate-reducing bcateria: past, present and future[J]. Anti-Corrosion Methods and Materials,1999,46(3):173~183.
  • 4EFIRD K D. Flow-Induced Corrosion[K]. USA: Uhlig' s Corrosion Handbook Publishment, 2000 : 233-248.
  • 5FOLQUER M E, RIBOTTA S B, REAL S G, et al. Study of Copper Dissolution and Passivation Processes by Electrochemical Impedance Spectroscopy[J]. Corrosion, 2002,56(2) : 240-246.
  • 6KEAR G, BARKER B D, STOKES K, et al. Electrochemical Corrosion Behaviour of 90-10 Cu-Ni Alloy in Chlofide-based Electrolytes[J]. Applied Electrochemistry, 2004,34( 1 ) : 659.
  • 7GB/T5836.1-2006,建筑排水用硬聚氯乙烯(PVCU)管材[S].
  • 8GB/T18742.2-2002,冷热水用聚丙烯管道系统[S].
  • 9杜娟,王洪仁,杜敏,李海涛.B10铜镍合金流动海水冲刷腐蚀电化学行为[J].腐蚀科学与防护技术,2008,20(1):12-18. 被引量:40
  • 10刘少峰,林乐耘.CU-Ni合金表面膜在海水中的转化行为[J].材料研究学报,1998,12(1):20-24. 被引量:13

共引文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部