摘要
通过分析某客运专线联调联试期间接触网检测超限值的情况,结合现场实际对该特殊地段接触网分段绝缘器位置设置进行设计优化,将分段绝缘器改造为绝缘锚段关节,满足了相应的功能需求,并对新建铁路接触网分段绝缘器的设计要求提出了参考建议。
By analyzing of out-limit values of OCS inspection during integrated commissioning of a passenger dedicated line, with connection to the actual conditions at site, the design has been optimized for position setting for OCS section insulator at this special section;the section insulator has been modified and transformed into the insulated overlap section, which is able to meet the functioning requirements. The paper puts forward accordingly the references and proposals for design of OCS section insulators on new construction of railways.
出处
《电气化铁道》
2019年第6期60-66,共7页
Electric Railway
关键词
接触网
分段绝缘器
硬点
联调联试
设计优化
OCS
section insulator
hard point
integrated commissioning
design optimization