Computational Fluid Dynamics Analysis of Shroud Design on Hemodynamic Performance and Blood Damage in a Centrifugal Blood Pump 被引量:1

下载PDF
导出
摘要 Patients with extracorporeal membrane oxygenation still suffer from high rates of complication that linked to the flow field within the blood pump.So it is essential to optimise the geometry of the pump.The specification of shroud design is arguably the necessary design parameter in the centrifugal pump.However,the hemodynamic performances of the different shroud designs have not been studied extensively.In this study,ten different shroud designs were made and divided into two groups as the different covering locations(A:Covering the blade leading edge,B:Covering the blade trailing edge).In every group,six shroud designs with the covering proportions of 0,1/5,2/5,3/5,4/5,1 were made.Detailed computational fluid dynamics(CFD)analyses were performed to investigate their effects on hemodynamics and hydraulic performance at the constant flow condition(4000 rpm,5 L/min).The percentage volumes of the scalar shear stress in specific threshold(τ<1 Pa:Thrombosis,τ>9 Pa:the destruction of von Willebrand factor,τ>50 Pa:Platelet activation,τ>150 Pa:Break of red blood)were used to compare the blood damage of the different shroud designs.Also,the modified index of hemolysis(MIH)were calculated based on a Eulerian approach for different pumps.CFD simulations predicted an increase in the pump head,hydraulic efficiency,a fraction of fluid volume with scalar shear stress values above a threshold(9 Pa,50 Pa,150 Pa)and MIH with increasing shroud covering proportions from 0 to 1 in the same covering location.Also,these above results were higher in group B than group A.This means that the risks of the hemolysis,thrombosis and bleeding increased as the rise of the covering proportion and they were higher in the pump whose shroud covers the blade trailing edge.
出处 《Computer Modeling in Engineering & Sciences》 SCIE EI 2018年第8期199-213,共15页 工程与科学中的计算机建模(英文)
基金 This work partly sponsored by the National Natural Science Foundation of China(Grant No.11602007,91430215,11572014) BJUT Foundation Fund(Grant No.015000514316007) Key research and development program(2016YFC0103201,2017YFC0111104) New Talent(015000514118002).
  • 相关文献

参考文献1

二级参考文献15

  • 1王芳群,封志刚,曾培,茹伟民,袁海宇,钱坤喜.基于CFD的离心式人工心脏泵的溶血预测方法[J].中国生物医学工程学报,2006,25(3):338-341. 被引量:8
  • 2MIZUNUMA H, NAKAJIMA R. Experimental study on shear stress distributions in a centrifugal blood pump [J]. Ar tif Organs, 2007, 31(7): 550-559.
  • 3FLUENT 14.0 User's Guide. l.ebanon (NH),Fluent Inc, 2011.
  • 4GARON A, FARINAS M I. Fast three-dimensional numeri- cal hemolysis approximation [J]. Artif Organs, 2004, 28 (11): 1016-1025.
  • 5SMITH WA, ALLAIRE P, ANTAKI J, et al. Collected nondimensional performance of rotary dynamic blood pumps [J]. ASAIOJ, 2004, 50(1): 25-32.
  • 6BLUDSZUWEIT C. Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump [J]. Artif Organs, 1995, 19(7): 590-596.
  • 7GIERSIEPEN M, WURZINGER LJ, OPITZR, et al. Esti marion of shear stress-related Blood damage in heart valve prostheses--in vitro comparison of 25 aortic valves [J]. Int J ArtifOrgans, 1990, 13(5)300-306.
  • 8SONG G, CHUA I. P, I.IM T M. Numerical study of a hio- centrifugal blood pump with straight impeller blade profiles [J]. ArtifOrgans, 2010, 34(2): 98-104.
  • 9APEL J, PAUl. R, KI.AUS S, et al. Assessment of hemoly- sis related quantities in a microaxial blood pump by computa- tional fluid dynamics [J]. Artif Organs, 2001, 25(5): 341- 347.
  • 10SONG G, CHUA L P, I.IM T M. Numerical study of a cen- trifugal blood pump with different impeller profiles [J]. ASAIO J, 2010, 56(1): 24-29.