南海某在役导管架平台牺牲阳极服役到期后需要延期服役15a,以在役平台的结构特征和服役环境为依据,从安装、可行性、可靠性和工程造价等方面对比分析了牺牲阳极和外加电流技术延寿技术的可行性。结果表明:相较于牺牲阳极法,外加电流延寿修复技术更加经济和便捷,采用阳极电缆拉伸和阳极远地安装方式,兼具经济性和安全性。
The sacrificial anode of an in-service jacket platform in the South China Sea needs to be extended for 15 years.Based on the structural characteristics and service environment of the in-service platform,the feasibility of the sacrificial anode and the applied current technology for life extension technology was analyzed from the aspects of installation,feasibility,reliability and engineering cost.The results show that the applied current extension repair technology was more economical and convenient than the sacrificial anode method,and the use of anode cable stretching and anode remote installation was both economical and safe.
作者
尹鹏飞
刘福国
张国庆
韩冰
张伟
杜翠薇
李向阳
李金梅
赵刚
YIN Pengfei;LIU Fuguo;ZHANG Guoqing;HAN Bing;ZHANG Wei;DU Cuiwei;LI Xiangyang;Li Jinmei;ZHAO Gang(Central Iron and Steel Research Institute,Beijing 100081,China;Offshore Oil Engineering Co.,Ltd.,Tianjin 300451,China;Qingdao NCS Testing and Protection Technology Co.,Ltd.,Qingdao 266071,China;School of Chemistry and Chemical Engineering,Sun Yat-sen University.Zhuhai 519000,China;Key Laboratory of Corrosion and Protection of Ministry of Education,Corrosion and Protection Center University of Science and Technology Beijing,Beijing 100083,China;Daqing Oilfield Engineering Co.,Ltd.,Daqing 163712,China)
出处
《腐蚀与防护》
CAS
北大核心
2019年第11期856-860,共5页
Corrosion & Protection
基金
国家科技基础条件平台专题服务项目(2005DKA10400-16Z1)
关键词
阴极保护
牺牲阳极
外加电流
延寿修复
导管架平台
cathodic protection
sacrificial anode
applied current
retrofit
jacket platform