摘要
以南宁地铁5号线工程为依托,结合地下车站防水工程实际,从设计要求、施工工艺、防水效果等方面,总结高分子自粘胶膜防水卷材在地铁施工中存在的问题,提出保证防水效果的控制方法及优化建议。
Based on the Nanning Metro Line 5 project and combining with the actual waterproofing engineering of underground stations,from the design requirements,construction technology,waterproof effect,etc.,this paper summarized the problems existing in the construction of polymer self-adhesive film waterproofing membranes and put forward the control methods and optimization suggestions to ensure the waterproof effect.
作者
徐富强
XU Fuqiang(China Railway 16th Bureau Group Co.Ltd.,Beijing 100018,China)
出处
《新型建筑材料》
北大核心
2019年第12期135-137,共3页
New Building Materials
关键词
预铺反粘法
高分子自粘胶膜防水卷材
地铁车站
结构渗漏
pre-laying anti-adhesion method
polymer self-adhesive film waterproof membrane
subway station
structural leakage