期刊文献+

氨气压缩机入口分离器液位上升原因分析与改造措施 被引量:1

CAUSE ANALYSIS OF LIQUID LEVEL RISE IN AMMONIA COMPRESSOR INLET SEPARATOR AND ITS MODIFICATION MEASURES
下载PDF
导出
摘要 介绍氨气压缩机工艺流程,分析氨气压缩机入口分离器液位上升的原因,认为一段分离器存在问题是主要原因。经过对氨气压缩机一段分离器进行改造与优化,解决一段分离器储液不足的问题,在系统开车时可节约数万元的费用,有效减轻了岗位人员的劳动强度。 The process of nitrogen compressor was described. The reasons of liquid level rise in ammonia compressor inlet separator were analyzed. It’s reckoned that the main reason existed in the first segment separator. After modification, the problem of insufficient liquid storage in the separator was solved. Tens of thousands of yuan was saved during system start-up, and labor forces were greatly reduced.
作者 钟天霖 Zhong Tianlin(CNOOC Huahe Coal Chemical Co.,Ltd.,Hegang 154100)
出处 《大氮肥》 CAS 2019年第6期393-395,共3页 Large Scale Nitrogenous Fertilizer Industry
关键词 氨气压缩机 入口分离器 液位上升 ammonia compressor inlet separator liquid level rise