摘要 为了获得3-PPR并联平台的最佳对位精度,针对平台的结构布局与工作影响因素对其对位精度的影响,采用理论误差分析与实验验证的方法对平台进行对位精度研究,得出平台误差数学模型并确定在速度为7.5 mm/s、加速度为100 mm/s 2时平台的对位精度最好,上述分析结果为进一步改善与开发平台性能提供了必要的理论依据,可用于各种高精密对位场合,具有一定的实际应用价值。 In order to obtain the optimal alignment accuracy of 3-PPR parallel platform,aiming at the impact of platform structure and work influencing factors on its alignment accuracy,the theoretical error analysis and experimental verification method are used to study the alignment accuracy of the platform.The mathematical model of the platform error was obtained and the alignment accuracy of the platform was best when the speed is 7.5 mm/s and the acceleration is 100 mm/s 2.The above analysis results provide the necessary theoretical basis for further improvement and development of the platform performance,which has certain practical application value for all kinds of high-precision alignment occasions.
作者 郑甲红 刘杰林 张弓 杨根 候至丞 王卫军 冯伟 韩彰秀 蔡君义 李友浩 ZHENG Jiahong;LIU Jielin;ZHANG Gong;YANG Gen;HOU Zhicheng;WANG Weijun;FENG Wei;HAN Zhangxiu;CAI Junyi;LI Youhao(School of Mechatronics Engineering,Shaanxi University of Science and Technology,Xi an Shaanxi 710021,China;Institute of Advanced Technology,Guangzhou Chinese Academy of Sciences,Guangzhou Guangdong 511458,China)
出处 《机床与液压》 北大核心 2019年第23期17-21,共5页 Machine Tool & Hydraulics
基金 广东省引进创新创业团队专项(2014ZT05G132) 广东省重大专项(2015B010919002) 深圳市海外高层次人才资金资助项目(KQTD2015033117354154)
关键词 高精密3-PPR并联平台 误差方程 正交试验 High precision 3-PPR parallel platform Error equation Orthogonal test
  • 相关文献

参考文献9

二级参考文献58

共引文献372

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部