期刊文献+

基于故障树分析方法的GIS支持绝缘子故障分析

Fault Analysis of GIS Support Insulator Based on FTA
下载PDF
导出
摘要 针对现有基于缺陷类型建立的气体绝缘金属封闭开关(GIS)故障树存在现场故障分析指导不足的缺点,文中通过对大量GIS故障案例分析,提出按照GIS中各类电气设备的故障机理建立故障树模型,在此基础上对发生的一起GIS支持绝缘子击穿故障进行全面分析,并提出加强同型号组合电器局部放电、SF6气体组分、红外热像等带电检测,加强GIS设备元件尤其支持绝缘子的质量监督,加强GIS设备的出厂和交接试验管理等防范措施,从而保证设备安全稳定运行。 The fault tree of GIS based on the defect type has the disadvantage of insufficient guidance of field fault analysis.In this paper,a large number of GIS fault cases are analyzed,and a fault tree model is established according to the fault mechanism of all kinds of electrical equipment in GIS.On this basis,a breakdown fault of GIS suppor-ting insulator is analyzed.It is proposed to strengthen the partial discharge,SF 6 gas composition,infrared thermal image and other live detection of the same type of combined electrical appliances,strengthen the quality supervision of GIS equipment components,especially the insulator,and strengthen the ex factory and handover test management of GIS equipment,so as to ensure the safe and stable operation of the equipment.
作者 朱大铭 张赛鹏 高楠楠 曹森 黄涛 董洪达 葛志成 陈捷元 ZHU Daming;ZHANG Saipeng;GAO Nannan;CAO Sen;HUANG Tao;DONG Hongda;GE Zhicheng;CHEN Jieyuan(State Grid Jilin Electric Power Co.,Ltd.,Changchun 130028,China;State Grid Jilin Electric Power Co.,Ltd.Electric Power Research Institute,Changchun 130021,China;State Grid Technology College,Jinan 250000,China;State Grid Yanbian Power Supply Company,Yanbian 133000,China)
出处 《吉林电力》 2019年第6期47-50,共4页 Jilin Electric Power
关键词 GIS 故障树分析方法(FTA) 支持绝缘子 击穿故障 GIS FTA supporting insulator breakdown fault
  • 相关文献

参考文献6

二级参考文献69

共引文献71