摘要
利用水洗脱氯和水泥固化对垃圾焚烧飞灰进行固化/稳定化处理,研究了液固比对焚烧飞灰中氯和重金属的脱除效果的影响,以及水泥添加量和养护时间对固化体密度、抗压强度和重金属浸出毒性的影响。结果表明:水洗过程对氯离子的脱除率为60.11%~74.64%,当液固比L/S=20 mL/g时,氯离子的脱除率达到最高的74.64%,但重金属Cr、Cu、Ni和Zn在水洗过程的脱除率都小于2%。随着水泥添加量和养护时间的增加,固化体密度和抗压强度呈逐渐增大趋势。当水洗焚烧飞灰含量为10%~70%时,固化体中重金属Cr、Cu、Ni和Zn的浸出浓度远低于GB 5085.3—2007规定的浸出阈值。
The water-washing dechlorination and cement solidification technology were used for the stabilization/solidification of municipal solid waste incineration fly ash.Effects of liquid-to-solid on the removal of chlorides and heavy metals were analyzed.Besides,the effects of cement addition on the density,compressive strength and leaching concenration of heavy mentals of solidified body were systematically studied.The results demonstrate that the removal rates of chlorides are 60.11%~74.64%during the processes of water-washing.The removal rate of chlorides reaches the maximum value of 74.64%when L/S was 20 mL/g,while those of heavy metals Cr,Cu,Ni,and Zn are below 2%.The density and compressive strenth of solidified body increase with the increase of cement addition.When the content of municipal solid waste incineration fly ash is ranged from 10%to 70%,the leaching concentrations of heavy metals Cr,Cu,Ni,and Zn are much lower than the limits suggested by China Standard of GB 5085.3—2007.
作者
张芝昆
王晶
李浩天
沈伯雄
ZHANG Zhi-kun;WANG Jing;LI Hao-tian;SHEN Bo-xiong(Key Laboratory of Pollution Control in Energy Utilization Process of Tianjin, School of Energy & Environmental Engineering, Hebei University of Technology, Tianjin 300401, China;School of Environmental Science & Technology, Dalian University of Technology, Dalian 116024, China)
出处
《科学技术与工程》
北大核心
2019年第35期395-401,共7页
Science Technology and Engineering
基金
国家自然科学基金(51808180)
河北省自然科学基金(E2018202180)
河北省高等学校青年拔尖人才计划(BJ2017032)
天津市自然科学基金重点项目(18JCZDJC39800)
唐山市科技项目(18130211A)
天津市科技项目(18ZXSZSF00040,18KPXMSF00080,18PTZWHZ00010)资助
关键词
垃圾焚烧飞灰
氯化物
水洗
水泥固化
重金属
municipal solid waste incineration fly ash
chlorides
water washing
cement solidification