摘要
以深圳地铁某车站为例,对其防水设计、施工过程及防水效果进行总结分析,结合其施工过程及渗漏情况分析渗漏产生的原因,从而探讨地铁车站防水施工的设计、施工技术要点,并提出改进措施。
Taking a station of Shenzhen metro as an example,the waterproof design,construction process and waterproof effect are summarized and analyzed.Combined with the construction process and leakage,the causes of leakage are analyzed to explore the design and construction of waterproof construction of subway station.Technical points and propose improvements.
作者
王升
张俞
Wang Sheng;Zhang Yu(Sinohydro Bureau 7 Co.,Ltd.,Chengdu 610000,China)
出处
《山西建筑》
2020年第1期94-96,共3页
Shanxi Architecture
关键词
地下车站
防水施工
防水原理
改进措施
underground station
waterproof construction
waterproof principle