摘要
为了解决潮湿地区医药仓库库内湿度长期偏高的问题,在对某工程案例进行实测的基础上,分析了造成湿度偏高的原因,并提出了采用温湿度独立控制系统的解决办法。通过方案比较及现场实验,表明了将溶液除湿新风机作为湿度控制方案,能有效解决医药仓库湿度偏高的问题。
In order to solve the problem of long-term high humidity in medical warehouses in humid areas, this paper analyses the causes of high humidity on the basis of an engineering case, puts forward the existing problems, and puts forward the solution of adopting independent temperature and humidity control system.By comparing several schemes and field experiments, it is concluded that the solution desiccant fresh air blower as a humidity control scheme is relatively reasonable and can effectively solve the problem of high humidity in medical storehouse.