期刊文献+

Estimation of drift limits for different seismic damage states of RC frame staging in elevated water tanks using Park and Ang damage index

Estimation of drift limits for different seismic damage states of RC frame staging in elevated water tanks using Park and Ang damage index
下载PDF
导出
摘要 Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to categorize the damage in quantifiable damage states. Among various parameters to quantify the damage states, the top drift of frame staging can be conveniently correlated to the different damage levels. In literature, drift limits corresponding to different damage states of the frame staging of the elevated water tank are not available. In the present study, drift limits for RC frame staging in elevated water tanks corresponding to different seismic damage states have been proposed. Various damage states of the elevated water tank have been determined using the Park and Ang damage index. The Park and Ang damage index utilizes results of both pushover analysis and incremental dynamic analysis. Twelve models of elevated water tanks have been developed considering variation in staging height and tank capacity. Incremental dynamic analysis has been performed using the suite of twelve actual earthquake ground motions. Based on the regression analysis between damage indexes and drift, limiting drift values for each damage state are proposed. Damage to elevated water tanks in past earthquakes can be attributed to the poor performance of their supporting frame staging. In order to ascertain the performance of these elevated water tanks, it is crucial to categorize the damage in quantifiable damage states. Among various parameters to quantify the damage states, the top drift of frame staging can be conveniently correlated to the different damage levels. In literature, drift limits corresponding to different damage states of the frame staging of the elevated water tank are not available. In the present study, drift limits for RC frame staging in elevated water tanks corresponding to different seismic damage states have been proposed. Various damage states of the elevated water tank have been determined using the Park and Ang damage index. The Park and Ang damage index utilizes results of both pushover analysis and incremental dynamic analysis. Twelve models of elevated water tanks have been developed considering variation in staging height and tank capacity. Incremental dynamic analysis has been performed using the suite of twelve actual earthquake ground motions. Based on the regression analysis between damage indexes and drift, limiting drift values for each damage state are proposed.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第1期161-177,共17页 地震工程与工程振动(英文刊)
关键词 elevated water tank frame staging damage states drift limit 3D modelling incremental dynamic analysis pushover analysis elevated water tank frame staging damage states drift limit 3D modelling incremental dynamic analysis pushover analysis
  • 相关文献

参考文献1

二级参考文献12

  • 1赵西安,钢筋混凝土高层建筑结构设计,1993年
  • 2吴波,博士学位论文,1993年
  • 3秦文欣,博士学位论文,1991年
  • 4欧进萍,地震工程与工程振动,1990年,10卷,4期
  • 5杜修力,国外地震工程,1988年
  • 6胡聿贤,地震工程学,1988年
  • 7江近仁,地震工程与工程振动,1987年,7卷,1期
  • 8陈永祁,建筑结构学报,1986年,7卷,1期
  • 9牛伯龙,同济大学学报,1981年,2期
  • 10团体著者,建筑结构抗震设计,1981年

共引文献145

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部