太西洗煤厂二次清洗型水力分级旋流器的试验研究 被引量:1

Experimental study for the secondary cleaning hydraulic classification hydro cyclones in Taixi Coal Preparation Plant
下载PDF
导出
摘要 为解决分级旋流器底流夹细的问题,太西洗煤厂对二次清洗型水力旋流器进行了工业试验;通过3因素7水平的均匀实验,探索了底流管直径、给料压力和清洗水压力对旋流器分级效率的影响;最佳工况条件为:底流管直径50 mm,给料压力250 kPa,清洗水压力40 kPa时,水力旋流器的分级效率达到了75.97%,此结果可作为工业生产的首选条件。 In order to solve the problem of fine underflow of classifying cyclone,Taixi Coal Washing Plant did an industrial trial for the secondary cleaning hydraulic classification hydrocyclones;The effect of underflow pipe diameter,feed pressure and cleaning water pressure on the classification efficiency of hydrocyclones was explored through the uniform experiment of 3 factors and 7 levels;the optimum condition is:in the situation of underflow pipe diameter 50 mm,feed pressure 250 kPa,cleaning water pressure 40 kPa,the classification efficiency of hydrocyclones reached 75.97%.This result can be taken as the first choice for factory production.
作者 魏英华 周立习 杨程 WEI Ying-hua(Ningxia Coal Industry Company of National Energy Group Washing Center,Shi Zui shan,Ning Xia 753000,China)
出处 《煤炭加工与综合利用》 CAS 2019年第12期4-6,11,I0001,共5页 Coal Processing & Comprehensive Utilization
关键词 选煤厂 水力分级旋流器 二次清洗 底流管直径 给料压力 工业试验 coal preparation plant hydraulic classification hydrocyclones secondary cleaning underflow pipe diameter feed pressure industrial trial
  • 相关文献

二级参考文献13

  • 1徐润继 罗茜.-[J].中国有色金属学报,1998,8(3):487-487.
  • 2徐继润,水力旋流器流场理论,1998年
  • 3罗茜,Int J Miner Process,1989年,25卷,297页
  • 4Hintze J O,湍流,1985年
  • 5徐继润,水力旋流器流场理论,1998年
  • 6Ji Hua,The 3rd China-Japan Int Conf on Filtr & Sep,1997年,360页
  • 7Chu Liangyin,Trans Nonferrous Met Soc China,1994年,4卷,4期,20页
  • 8罗茜,Int J Miner Process,1989年,25卷,297页
  • 9黄永念(译),湍流,1985年
  • 10徐继润,水力旋流器流场理论,1998年

共引文献33