摘要 目的探究液相色谱―串联质谱仪(liquid chromatography-tandem mass spectrometer,LC-MS/MS)检测饲料中克伦普罗时,环天冬氨酰苯丙氨酸对试验干扰的原因,在此基础上探究出应用LC-MS/MS分析的确证技术与方法。方法应用四极杆―轨道阱高分辨质谱仪和LC-MS/MS对环天冬氨酰苯丙氨酸、克伦普罗对照品以及含有环天冬氨酰苯丙氨酸的饲料样品进行分析。结果饲料中含有环天冬氨酰苯丙氨酸对克伦普罗的检测干扰的原因为二者母离子及2个子离子的质荷比很接近,且二者离子丰度比也很接近。应用LC-MS/MS分析的确证技术与方法为梯度碎裂离子片段依次匹配比较法。结论应用LC-MS/MS检测会遇到假阳性的问题,这是串联质谱结构与方法原理决定的;建议调整克伦普罗的2个子离子为263.07>168.04,263.07>132.06;用LC-MS的梯度碎裂离子片段依次匹配比较法准确、实用。 Objective To study the cause of interference of cycloaspartyl phenylalanine in the detection of clenbuterol in feedstuffs by liquid chromatography-tandem mass spectrometry(LC-MS/MS),and on this basis to study the confirmation technology and method of LC-MS/MS analysis. Methods Quadrupole-orbital trap high resolution mass spectrometer and LC-MS/MS were used to analyze cycloaspartyl phenylalanine,clenbuterol reference substance and feed samples containing cycloaspartyl phenylalanine. Results The reason for the interference of cycloaspartic phenylalanine in the feed to the detection of clenbuterol was that the plasma-charge ratio of the parent ion and the two daughter ions were very close,and the ion abundance ratio of the two was also very close. The confirmation technique and method of LC-MS/MS analysis are gradient fragmentation ion fragment matching comparison method. Conclusion The application of LC-MS/MS will encounter the problem of false positives,which is determined by the structure and principle of tandem mass spectrometry. It is suggested to adjust the two sub-ions of clenbuterol to 263.07>168.04 and 263.07>132.06. It is accurate and practical to use LC-MS gradient fragmentation ion fragments to match comparison method in sequence.
作者 于家丰 卞苏敏 杨莹 商方方 李俊 YU Jia-Feng;BIAN Su-Min;YANY Ying;SHANG Fang-Fang;LI Jun(Liaoning inspection and testing certification center,Shenyang 110016,China;Shenyang Social Welfare Institute,Shenyang 110165,China;Yunan Testing&Inspection Institute for Veterinary Drugs&Feedstuff,Kunming 650201,China;Feed Research Institute of Chinese Academy of Agricultural Sciences,Beijing 100081,China)
出处 《食品安全质量检测学报》 CAS 2019年第24期8489-8498,共10页 Journal of Food Safety and Quality
关键词 克伦普罗 环天冬氨酰苯丙氨酸 液相色谱―串联质谱仪 四极杆―轨道阱高分辨质谱仪 饲料 clenbuterol cycloaspartic phenylalanine liquid chromatography-tandem mass spectrometer quadrupole-orbital trap high resolution mass spectrometer feed
  • 相关文献

参考文献15

二级参考文献143

共引文献135

同被引文献5

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部