针对传统主动频率偏移法通过逆变器注入畸变的扰动电流检测孤岛效应,产生了较大的谐波畸变、容性负载下检测速度慢甚至超出规定的检测时间导致检测失败等问题,提出了一种通过改变相位使基波分量发生必要偏移的新型电流扰动式孤岛检测方法。与传统主动频率偏移法相比,该方法检测速度更快,总谐波畸变率更小。通过Matlab建模仿真验证了该方法的可行性和优越性。
Aiming at the problem that the traditional active frequency drift method detects the islanding effect through the disturbance current of the inverter injection distortion,the total harmonic distortion rate is large,the detection speed is slow under capacitive load and even exceeds the prescribed detection time,which leads to the detection failure,a novel current disturbance islanding detection method was proposed,which can shift the fundamental component by changing the phase.Compared with the traditional active frequency drift method,the detection speed is faster than that of the traditional active frequency drift method.The simulation results of Matlab show the feasibility and superiority of this method.
作者
郑伟航
肖伸平
张晓虎
ZHENG Weihang;XIAO Shenping;ZHANG Xiaohu(School of Electrical and Information Engineering,Hunan University of Technology,Zhuzhou 412007,Hunan,China;Key Laboratory for Electric Drive Control and Intelligent Equipment of Hunan Province,Zhuzhou 412007,Hunan,China)
出处
《电气传动》
北大核心
2020年第1期95-99,共5页
Electric Drive
基金
国家自然科学基金(61672225)
湖南省自然科学基金(2017JJ4021)
关键词
主动频率偏移法
主动法
检测速度
谐波
active frequency drift method
active method
detection speed
harmonic