摘要
新建及大修后的火电机组因热力系统杂物多容易在凝汽器中积聚杂质,所以常规上都设计有凝汽器出口滤网。而该滤网堵塞后会引起凝泵断水,对凝泵安全运行造成威胁。分析一起凝汽器出口滤网因杂质堵塞造成凝泵断水的故障,并对凝结水系统提出改进方案,保障了设备安全运行。
Since various impurities exist in the thermal system of the newly built and overhauled thermal power units and are easy to accumulate in the condenser,the filter screen is usually designed for condenser outlet.When the filter screen is blocked,the water flow of the condensate pump will be cut off,threatening the safe operation of the condensate pump.This paper analyzes a water cut-off fault of the condensate pump caused by impurities blocking at the outlet filter screen of the condenser,and puts forward an improvement scheme for the condensate system to ensure the safe operation of the equipment.
作者
张正峰
田宁
ZHANG Zhengfeng;TIAN Ning(Shaanxi Shangluo Power Generation Co.,Ltd.,Shangluo 726007,Shaanxi Province,China)
出处
《电力安全技术》
2019年第10期29-31,共3页
Electric Safety Technology
关键词
凝结水泵
凝汽器
滤网堵塞
断水故障
condensate pump
condenser
filter screen blockage