期刊文献+

某电厂脱硝系统蒸汽耗量过大问题分析 被引量:1

Analysis of Excessive Steam Consumption in Denitration System of a Power Plant
下载PDF
导出
摘要 某电厂脱硝系统还原剂改造后,机组日补水量增加了约70t,蒸汽耗量测量值远大于设计值。通过对设备耗汽量、蒸汽流量测量装置、系统耗水量三方面进行分析,找出问题所在和机组的真实耗汽量。 After the reduction agent transformation of denitration system in a power plant,the daily water supply of the unit increased by about 70 tons,and the measured value of steam consumption was far greater than the design value.Through the analysis of the steam consumption of the equipment,the steam flow measuring device and the water consumption of the system,the problem and the real steam consumption of the unit are found out.
作者 薛晓东 Xue Xiao-dong
出处 《化工设计通讯》 CAS 2019年第12期119-120,共2页 Chemical Engineering Design Communications
关键词 脱硝系统 尿素水解 涡街流量计 蒸汽耗量 denitration system urea hydrolysis vortex flowmeter steam consumption
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部