期刊文献+

光学相干断层扫描仪与脉络膜厚度 被引量:1

Optical Coherence Tomography and Choroid Thickness
下载PDF
导出
摘要 目的总结脉络膜厚度与光学相干断层扫描仪器的相关发现。方法我们系统地总结了用光学相干断层扫描仪测量的脉络膜厚度的影响因素,以及在各种眼科疾病中的改变,并且描述了厚度与血流之间的关系。结果光学相干断层扫描仪测量获得的脉络膜厚度受到许多因素的影响,例如年龄,性别,眼轴,是否吸烟等等,脉络膜厚度在各种眼科疾病中有不同的表现,而血流与厚度之间存在着相关关系。结论光学相干断层扫描仪可以作为测量脉络膜厚度的工具。 Objective To summarize the relevant findings of choroidal thickness and optical coherence tomography instruments.Methods We systematically summarized the influencing factors of choroidal thickness measured by optical coherence tomography,as well as changes in various ophthalmic diseases,and described the relationship between thickness and blood flow.Results The choroidal thickness measured by optical coherence tomography was affected by many factors,such as age,gender,axial length,smoking,etc.The choroidal thickness was different in various ophthalmic diseases,while blood flow and thickness There is a correlation between them.Conclusion Optical coherence tomography can be used as a tool to measure choroidal thickness.
作者 周莹 武志峰 邹文军 ZHOU Ying;WU Zhifeng;ZOU Wenjun(Department of Ophthalmology,Second People’s Hospital of Wuxi City,Affiliated to Nanjing Medical University,Wuxi Jiangsu 214002,China)
出处 《中国医疗设备》 2019年第S01期77-78,共2页 China Medical Devices
基金 国家自然科学青年科学基金项目(81700852)
关键词 脉络膜厚度 血流 光学相干断层扫描仪 choroidal thickness(CT) blood flow optical coherence tomography(OCT)
  • 相关文献

参考文献1

二级参考文献16

  • 1Moreno TA, O'Connell RV, Chiu SJ, et al. Choroid development and feasibility of choroidal imaging in the preterm and term infants utilizing SD-OCT[J]. Invest Ophthalmol Vis Sci, 2013, 54(6) : 4140-4147.
  • 2Farias LB, Lavinsky D, Schneider WM, et al. Choroidal thickness in patients with diabetes and microalbuminuria [ J ]. Ophthalmology, 2014 , 121 (10) :2071-2073.
  • 3Querques G, Lattanzio R, Querques L, et al. Enhanced depth imaging optical coherence tomography in type 2 diabetes [ J ]. Invest Ophthalmol Vis Sci, 2012, 53(10) :6017-6024.
  • 4Motaghiannezam R, Schwartz DM, Fraser SE. In vivo human choroidal vascular pattern visualization using high-speed swept- source optical coherence tomography at 1060 nm [ J ]. Invest Ophthalmol Vis Sci, 2012, 53 (4) :2337-2348.
  • 5Esmaeelpour M, Povazay B, Hermann B, et al. Mappingchoroidal and retinal thickness variation in type 2 diabetes using three-dimensional 1060-nm optical coherence tomography [ J ]. Invest Ophthalmol Vis Sci, 2011, 52(8) :5311-5316.
  • 6Wilkinson CP, Ferris FL 3rd, Klein RE, et al. Proposed international clinical diabetic retinopathy and diabetic macular edema disease severity scales [ J ]. Ophthalmology, 2003, 110 (9) :1677-1682.
  • 7Early Treatment Diabetic Retinopathy Study Research Group. Photocoagulation for diabetic macular edema: Early Treatment Diabetic Retinopathy Study report number 1 [ J ]. Arch Ophthalmol, 1985,103(12) :1796-1806.
  • 8Hirooka K, Saito W, Hashimoto Y, et al. Increased macular choroidal blood flow velocity and decreased choroidal thickness with regression of punctate inner choroidopathy [ J ]. BMC Ophthalmol, 2014, 14:73.
  • 9Rabman W, Chen FK, Yeoh J, et al. Repeatability of manual subfoveal choroidal thickness measurements in healthy subjects using the technique of enhanced depth imaging optical coherence tomography[ J]. Invest Ophthalmol Vis Sei, 2011,52(2) :2267- 2271.
  • 10Schocket LS, Brucker AJ, Niknam RM, et al. Foveolar choroidal hemodynamics in proliferative diabetic retinopathy E J ]. Int Ophthalmol, 2004, 25 (2) : 89-94.

共引文献21

同被引文献17

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部