摘要 WR-42功率基准是一套微量热计系统,利用直流替代及量热技术对被测热敏电阻型功率座的有效效率进行定标。对WR-42功率基准系统中有效效率不确定度评定的过程进行了介绍,并给出了有效效率的测量结果与不确定度的评定结果。该基准的研制成功,填补了18~26.5 GHz频段的空白,结合其它功率基准,使我国射频与微波功率计量基准频段从10 MHz连续覆盖到了220 GHz。 The WR-42 power standard is a micro-calorimeter system that uses DC substitution and calorimetry techniques to measure the effective efficiency of the WR-42 thermistor mount.The uncertainty assessment of effective efficiency in WR-42 micro-calorimeter system is introduced,and the measurement results of effective efficiency and uncertainty are given.The development of this power standard fills the gap between 18 GHz and 26.5 GHz,which help Chinese RF power standard fully cover the frequency band between 10 MHz and 220 GHz.
作者 谷若晨 袁文泽 丁娜 崔孝海 李勇 GU Ruo-chen;YUAN Wen-ze;DING Na;CUI Xiao-hai;LI Yong(National Institute of Metrology,Beijing 100029,China)
出处 《计量学报》 CSCD 北大核心 2020年第1期100-102,共3页 Acta Metrologica Sinica
关键词 计量学 功率基准 微量热计 直流替代 WR-42 不确定度 metrology power standard micro-calorimeter DC substitution WR-42 uncertainty
  • 相关文献

参考文献5

二级参考文献17

  • 1Weijie Sun, Xiaohai Cui, Yong Li. Research the Method of evaluation microwave power standard correction factor Uncertainty based on the theory of electromagnetic field. Applied Mechanics and Materials Vols. 333 - 335 (2013) pp284 - 289.
  • 2朱大成.WR22微波功率基准-微量热计的研制.中国计量科学研究院硕士学位论文,2012.
  • 3毫米波国家功率基准及其国际关键比对.中国科技成果.2012.
  • 4Crowley T P, Cui X H. Design and evaluation of a WR-15 (50 to 75 GHz) microcalorimeter [ C ]// CPEM 2008 Conference, Broomfield, Colorado, USA, 2008.
  • 5Allen J W, Fred R C, Larsen N T, et al. The NIST Microwave Power Standards in Waveguide [ R ]. NIST Technical Note 1511, 1999.
  • 6Cui X H, Crowley T P. Comparison of Experimental Techniques for Evaluating the Correction Factor of a Rectangular Waveguide Microcalorimeter [ C ]//IEEE Transactions on Instrumentation and Measurement, Daejeon, Korea,2010.
  • 7T P Crowley,Xiaohai Cui. Design and Evaluation of a WR-15 (50 to 75 GHz)Microcalorimeter[J].CPEM 2008 Conference Broomfield CO USA,2008.
  • 8J Wayde Allen,Fred R Clague,Neil T Larsen Manly P Weidman. NIST Microwave Power Standards in Waveguide[J].NIST Technical Note 1511,1999.
  • 9Xiaohai Cui,T. P. Crowley. Comparison of Experimental Techniques for Evaluating the Correction Factor of a Rec-tangular Waveguide Microcalorimeter[J].IEEE Transac-tions on Instrumentation and Measurement,.
  • 10Rolf Judaschke. CIPM key comparison CCEM. RF-K25. W‘RF power from 33 to 50 GHz in waveguide ’Technical protocol[A].2011.

共引文献9