摘要 福建省一电厂在现有设备未进行改造的基础上,通过低负荷试验、燃烧优化调整等对电厂300 MW亚临界燃煤机组的深度调峰能力进行验证。同时,就300 MW机组参与深度调峰的安全性和经济性进行分析,以期为同类机组深度调峰运行及改造提供参考和借鉴。 A power plant in Fujian Province verified the deep peak load regulation capacity of 300 MW subcritical coal-fired unit through low load test and combustion optimization adjustment on the basis of existing equipment not being modified. At the same time, the safety and economy of 300 MW units participating in deep peak load regulation were analyzed in order to provide reference for the operation and transformation of similar units.