摘要
紧密结合乏燃料后处理蒸汽凝结水回收利用及通风加热、制冷需求,分冬夏季工况,采用Li Br制冷机组和空气加热器,设计蒸汽凝结水回收利用系统流程。分析系统运行工况,给出设备选型和空气处理参数,从而分析节能效果。
According to the requirements of steam condensate water recovery,ventilation,heating and refrigeration after spent fuel treatment,LiBr refrigeration unit and air heater were adopted in winter and summer to design the process of steam condensate water recovery and utilization system.This paper analyzed the operating conditions of the system,gave the equipment selection and air treatment parameters,so as to analyze the energy-saving effect.
作者
李园园
郑雨兰
杨少东
LI Yuanyuan;ZHENG Yulan;YANG Shaodong(China Nuclear Power Engineering Co.,Ltd.,Beijing 100840,China)
出处
《能源与节能》
2020年第1期66-67,共2页
Energy and Energy Conservation
基金
科工局后处理重大专项研究成果(科工二司〔2017〕1474号)
关键词
蒸汽凝结水
LiBr制冷机组
送风处理
空气处理参数
steam condensate water
LiBr refrigeration unit
air supply processing
air treatment parameters