多台磨断煤导致主汽温速降跳机的事故分析

Analysis of Tripping Accident Caused by the Coal of Several Coal Mills Being Cut Off
下载PDF
导出
摘要 介绍了某电厂多台磨煤机长时间、反复断煤致使锅炉炉膛温度降低而导致的机组跳闸事故,阐述了事故过程,分析了事故的主要原因、直接原因和间接原因,同时提出了相应的预防措施,以供同类型电厂参考。 The tripping accident in a power plant is introduced, which is due to the low temperature of boiler chamber temperature caused by the repeated cut off of coal feeding of several coal mills for a long time. The main causes, direct causes and indirect causes of the accident are analyzed. Meanwhile, the corresponding preventive measures are put forward for the reference of similar power plants.
作者 王彦领 王浩 蒙在朗 范晓辉 WANG Yanling;WANG Hao;MENG Zailang;FAN Xiaohui(Pingdingshan Power Generation Company of State Power Investment Henan Power Generation Co.,Ltd.,Pingdingshan 467312,Henan Province,China;State Power Investment Henan Power Generation Co.,Ltd.,Zhengzhou 450016,Henan Province,China)
出处 《电力安全技术》 2019年第12期60-63,共4页 Electric Safety Technology
关键词 磨煤机 主汽温度 跳机事故 coal mills main steam temperature tripping accident
  • 相关文献

参考文献1

二级参考文献3

  • 1杨晓华.降负荷时防止锅炉灭火的稳燃措施[J].电力安全技术,2009,11(3):58-59. 被引量:4
  • 2容恩.300MW火力发电机组丛书(第一分册燃煤锅炉机组)[M].北京:中国电力出版社,1998.
  • 3山西电力工业局.发电厂集控运行(中级工)[M].北京:中国电力出版社,1998.

共引文献1